background image

page | 6

REAR PANEL

ESA-70V2CH-150W, 300W

ETHERNET

 12V TRIGGER

IN

OUT

LOOP

OUT

CH1

CH2

UNBALANCED

INPUTS

 BALANCED INPUTS

CH3 CH4

LEVEL

CH1

CH2

SPEAKER OUT

CH1

CH2

+

_

+

R

UTILISER UN FUSIBLE DE RECHANGE

D E M E M E T Y P E E T C A L I B R E .

ATTENTION:

FOR CONTINUED PROTECTION AGAINST

RISK OF FIRE, REPLACE ONLY WITH

SAM TYPE FUSE

AND RATING.

CAUTION:

E

S

 IR RS232 

TxRx In1

In2

DRY

CONTACT

G G

+

_

+

_

G

G

_

100/120V~60Hz 3.15A

T3.15A L 250V

220/240V~50Hz 1.6A

T1.6A L 250V

VOLTAGE

SWITCH ON

BOTTOM

ESA-70V2CH-500W

ETHERNET

 12V TRIGGER

IN

OUT

LOOP

OUT

CH1

CH2

UNBALANCED

INPUTS

 BALANCED INPUTS

CH3 CH4

+

_

+

_

LEVEL

CH1

CH2

SPEAKER OUT

CH1 CH2

+

_ _

+

R

UTILISER UN FUSIBLE DE RECHANGE

D E M E M E T Y P E E T C A L I B R E .

ATTENTION:

FOR CONTINUED PROTECTION AGAINST

RISK OF FIRE, REPLACE ONLY WITH

SAM TYPE FUSE

AND RATING.

CAUTION:

E

100/120V~60Hz 10A

T10A L 250V

S

 IR RS232 

TxRx

220/240V~50Hz 5A

T5A L 250V

In1

In2

DRY

CONTACT

G G

G

G

VOLTAGE

SWITCH ON

BOTTOM

A.  Ethernet Port

RJ45 port for connecting an Ethernet Cat5e/6 cable for IP control of the amplifier.

B.  IR

Control the amplifier via IR from your control system. This input accepts a mono connector 
– Signal and GND only, no 12V signal supplied.

C.  RS-232

To communicate with a control system or PC for serial control of the amplifier.

D.  Dry Contact

Use dry contact to toggle amp ON/OFF, or mute/unmute. Setup through web GUI.

E.  12 Volt Trigger IN and OUT

When 4.5-15 Volts DC are applied to 12V IN, amplifier will turn on. When voltage is 
dropped, amplifier turns back off. 12V OUT allows other equipment to be controlled from 
the same 12V signal.

F.  Loop Outputs 1 & 2

Unbalanced mono RCA connections for sending audio to other devices.

G.  Unbalanced Inputs 1 &2

Unbalanced mono RCA input connections for connection of sources.

H.  Balanced Inputs 3 & 4

Set-screw connections for sources with balanced output.

I.  Input Level Adjustment Dials

Digital encoder to adjust input volume levels. Turn clockwise to send volume increase 
commands and counter-clockwise to send volume decrease commands.

A

E

G

F

B

C

D

H

I

J

L

K

A

E

G

F

B

C

D

H

I

J

L

K

Содержание ESA-70V2CH-150W

Страница 1: ...D INPUTS BALANCED INPUTS CH3 CH4 LEVEL CH1 CH2 SPEAKER OUT CH1 CH2 _ _ R UTILISER UN FUSIBLE DE RECHANGE D E M E M E T Y P E E T C A L I B R E ATTENTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE R...

Страница 2: ...htning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the apparatus has beendamaged in any way such as power supply cord o...

Страница 3: ...erlesblessuresencasderenversement 13 D branchez cet appareil pendant les orages ou lorsqu il n est pas utilis pendant de longues p riodes de time Refer un technicien qualifi personnel Une r paration e...

Страница 4: ...ith low heat output thanks to digital amplification and massive power output in a small 1U and 2U package these amplifiers are guaranteed to perform Contents 1x ESA 70V2CH 150 300 500W Amplifier 4x Re...

Страница 5: ...ED Indicates whether a channel is operating correctly or is in protection BLUE Normal RED Protection Indicates an issue with installation or setup C Output Level Meter Level meter flashes green to ind...

Страница 6: ...TCH ON BOTTOM A Ethernet Port RJ45 port for connecting an Ethernet Cat5e 6 cable for IP control of the amplifier B IR Control the amplifier via IR from your control system This input accepts a mono co...

Страница 7: ...n based on the voltage available NOTE The ESA 70V2CH includes an IEC cable meant for use with a NEMA 5 15 receptacle supplying 115V AC power For countries utilizing 230V AC power the cable can be swap...

Страница 8: ...ted on both sides of the unit Do not place the unit on carpeting or any similar material Do not install the unit near a source of heat or in an extremely humid or wet location If your installation lac...

Страница 9: ...ent rack The amplifier will occupy 1U of rack space Ensure that the unit is in a well ventilated area that provides adequate cooling Free air space is required above the amplifier and below the amplif...

Страница 10: ...nals out from the UNBALANCED INPUT of the channel 12V TRIGGER IN OUT LOOP OUT CH1 CH2 UNBALANCED INPUTS BALANCED INPUTS CH3 CH4 LEVEL CH1 CH2 SPEAKER OUT CH1 CH2 _ S IR RS232 TxRxIn1 In2 DRY CONTACT G...

Страница 11: ...TheESA 70V2CH IP receives control data on pin 2 RxD Data Receive and transmits control data on pin 3 TxD Data Transmit See the diagram below for details Pin Function 2 RxD Data Receive 3 TxD Data Tra...

Страница 12: ...r trigger control and daisy chain control of more than one amplifier To utilize the 12V DC trigger function attach a mono mini cable between the 12V trigger output of the controlling device and the 12...

Страница 13: ...2 CH 2 Zone 1 Ch 1 ETHERNET 12V TRIGGER IN OUT LOOP OUT CH1 CH2 UNBALANCED INPUTS BALANCED INPUTS CH3 CH4 LEVEL CH1 CH2 SPEAKER OUT CH1 CH2 _ _ R UTILISER UN FUSIBLE DE RECHANGE D E M E M E T Y P E E...

Страница 14: ...gnal or distortion of highs and lows To eliminate this issue re adjust the volume levels by starting at baseline settings and re adjusting the final volume so that a maximum comfortable volume level c...

Страница 15: ...ensitivity 2 5mV 12 Volt Trigger Input 4 5 12V DC 10K 12 Volt Trigger Output 12V DC 10mA S N ratio 95db A weighted Frequency Response 50 Hz to 20KHz Distortion 0 1 THD 20 Hz 20 kHz Input Voltage 115V...

Страница 16: ...on Input Output and use the OUTPUT test tone function to test if each output can produce sound 2 Verify correct source operation and input wiring Turn volume in source up to an audible level 3 Is Powe...