page | 6
www.snapav.com Support 866.838.5052
Back panel
EA-RSP-16D-100
EA-RSP-2D-200
A. Analog inputs:
Local line-level inputs, analog RCA unbalanced type.
B. Analog loop outputs:
Stereo RCA input loop outputs, RCA unbalanced type.
C. Zone SPEAKER OUTPUTS:
4-position Phoenix-style connectors (8-, 12-, and 16-channel models) and 5-way
binding posts (2-channel model) for speaker wiring connections.
D. SUBWOOFER OUTPUTS:
Each zone of the amplifier has a subwoofer analog RCA unbalanced-type output.
This output will be comprised of both a left and right channel summed together and includes a fixed
low-pass filter, set at 200 Hz.
Note:
Low-pass filter settings from DSP presets will affect only the speaker
outputs, not these outputs.
E. IR STATUS:
LED illuminates when the IR signal is received.
F. IR IN:
3.5 mm stereo port. The adaptive IR input circuit supports 38 KHz carrier frequencies.
G. TRIG IN:
3.5 mm port, used to accept a voltage trigger (4.5V-12V) from an external device, to turn on the
amplifier or put it into standby.
H. RESET:
A recessed micro-controlled push button.
• Quick momentary press = reboot
• Hold RESET button for 5 seconds = Returns network settings to DHCP default
• Hold RESET button for 10+ seconds = Return the device to its factory default configuration.
I. Power switch
J. IR power ON/OFF:
If on, +12V DC is applied to the IR IN jack, providing power for an external IR receiver.
Note:
Do
not turn on IR power if a direct connection to a control system is used.
K. IR OUT:
3.5 mm port, used for looping IR out to additional amplifiers or devices.
L. TRIG OUT:
3.5 mm port, used for looping voltage trigger out to additional amplifiers or devices.
M. NETWORK:
Standard RJ45 connector with LED indicator. 10/100 Ethernet. Port remains active when amp is
in Standby mode.
N. Power connector:
Use the supplied power cord to connect power.