background image

page | 3

9. 

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades 

with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide 

blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult 

an electrician for replacement of the obsolete outlet.

10. 

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and 

the point where they exit from the apparatus.

11. 

Only use attachments/accessories specified by the manufacturer.

12. 

Use only with the cart, stand, tripod, bracked, or table specified by the manufacturer, or sold with the 

apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury 

from tip-over.

13. 

Unplug this apparatus during lighting storms or when unused for long periods of time.

14. 

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 

damaged in any way, such as a damaged power-supply cord or plug, liquid has been spilled or object has 

fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or 

has been dropped.

15. 

Protective Ground Terminal: The apparatus shall be connected to an AC main socket with a protective earth 

ground connection.

Warnings

Warning: To reduce the risk of electric shock, do not remove cover (or back), no user-serviceable parts inside. 

Refer servicing to qualified service personnel.
Avertissement : pour réduire le risque d’électrocution, ne retirez pas le couvercle (ou l’arrière) de l’appareil. Les 

pièces se trouvant à l’intérieur ne sont pas réparables par l’utilisateur. Adressez-vous à un technicien qualifié.

This lightning flash with an arrow head symbol, within an equilateral triangle, is intended to alert the user to the 

presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude 

to constitute a risk of electric shock to the person. 
Cette flèche en forme d’éclair dans un triangle équilatéral attire l’attention de l’utilisateur sur la présence d’une 

« tension dangereuse » non isolée à l’intérieur du châssis de l’appareil susceptible de présenter un risque 

d’électrocution.

This exclamation point within an equilateral triangle is intended to alert the user to presence of important 

maintenance (servicing) instructions in the literature accompanying the appliance.
Ce point d’exclamation à l‘intérieur d’un triangle équilatéral attire l’attention de l’utilisateur sur la présence de 

consignes de maintenance importantes (entretien) dans les documents accompagnant l’appareil.

AC voltage: This symbol indicates that the rated voltage marked with the symbol is AC voltage.
CAUTION: FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE OF FUSE.

REGULATORY INFORMATION

United States—FCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s 

authority to operate the equipment.

Note: 

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to 

part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not 

installed and used in accordance with the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 

Содержание EA-RSP-12D-100

Страница 1: ...INSTALLATION MANUAL Response Series DSP Amplifiers EA RSP 2D 200 EA RSP 8D 100 EA RSP 12D 100 EA RSP 16D 100...

Страница 2: ...l time volume and mute status for connected user interfaces Independent input gain for each source with optional anti clipping feature providing consistent levels when switching between sources Each o...

Страница 3: ...ar l utilisateur Adressez vous un technicien qualifi This lightning flash with an arrow head symbol within an equilateral triangle is intended to alert the user to the presence of un insulated dangero...

Страница 4: ...t susceptible d en compromettre le fonctionnement Recycling Correct Disposal of Waste Electrical and Electronic Equipment WEEE by User in Private Households in the EU This symbol on the product or acc...

Страница 5: ...the amplifier s operating state Each channel has one bi color LED for each zone LED functionality Blue LED solid Amplifier is on and functioning properly Red LED solid Amplifier is on but is not func...

Страница 6: ...arrier frequencies G TRIG IN 3 5 mm port used to accept a voltage trigger 4 5V 12V from an external device to turn on the amplifier or put it into standby H RESET A recessed micro controlled push butt...

Страница 7: ...place the side amplifier up against other components or cabinets Doing either of these things will block ventilation openings ATTENTION Pour pr venir les dommages toujours conserver un espace d une u...

Страница 8: ...les entr s tandis que l amplificateur est actionn peuvent causer le choc et pourraient endommager l amplificateur D branchez le cordon de secteur avant d tablir des rapports CONNECTING NETWORK AND POW...

Страница 9: ...ers can also be wired to bridge channels to increase the power available to the speakers CAUTION Check the polarity of the speaker and wire before connecting to the amplifier ATTENTION V rifiez la pol...

Страница 10: ...ed to two bridge inputs using two zones to create a bridged stereo output 4 Set the Bridge Mode ON through the browser user interface USING THE BROWSER USER INTERFACE 1 Connect an Ethernet Cat5E 6 cab...

Страница 11: ...tings in the DSP PRESET list 8 Edit presets in the DSP PRESET EDIT menu including frequency response limiter EQ crossover high pass low pass and delay For in depth information on DSP presets and the b...

Страница 12: ...o is sensed for 15 minutes default However this time setting can be changed or Standby mode can be disabled If Standby mode is disabled the amplifier turns off only when the front power button is pres...

Страница 13: ...the amplifier turns off only when an IP or IR power command is received See Standby Settings below for more information Note The Standby wakeup time varies based on the selected Power Mode and amplifi...

Страница 14: ...ed biquad low pass filter at 200 Hz 6 dB octave slope Analog loop outputs Output 2 Vrms at 10K ohm impedance load Power output 8 2 channels driven 2x50W 1 kHz 2 100W 1 kHz Power output 4 2 channels dr...

Страница 15: ...16D 100 EA RSP 2D 200 Front power LED Blue LED light bar System status LED Bi color LED 8 Bi color LED 12 Bi color LED 16 Bi color LED 2 Ethernet 1 x RJ45 with LED Factory restore button Yes Dimension...

Страница 16: ...2020 Wirepath Home Systems LLC Rev 20 07 09 0830...

Отзывы: