![Epever XTRA Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/epever/xtra-series/xtra-series_user-manual_2417345014.webp)
8
*
Isc=short circuit current(amps) Voc=open circuit voltage.
Model
Max. PV input current
Max. PV wire size
*
XTRA1206N
XTRA1210N
10A
4mm
2
/12AWG
XTRA2206N
XTRA2210N
20A
6mm
2
/10AWG
XTRA3210N
XTRA3215N
XTRA3415N
30A
10mm
2
/8AWG
XTRA4210N
XTRA4215N
XTRA4415N
40A
16mm
2
/6AWG
*
These are the maximum wire sizes that will fit the controller terminals.
CAUTION
When the PV modules are connected in series, the open-circuit voltage of the
PV array must not exceed 46V (XTRA**06N), 92V (XTRA**10N), 138V
(XTRA**15N) at 25
℃
environment temperature.
Battery and Load Wire Size
The battery and load wire size must conform to the rated current. The reference size is as below:
Model
Rated
charge
current
Rated
discharge
current
Battery wire size
Load wire
size
XTRA1206N
XTRA1210N
10A
10A
4mm
2
/12AWG
4mm
2
/12AWG
XTRA2206N
XTRA2210N
20A
20A
6mm
2
/10AWG
6mm
2
/10AWG
XTRA3210N
XTRA3215N
XTRA3415N
30A
30A
10mm
2
/8AWG
10mm
2
/8AWG
XTRA4210N
XTRA4215N
XTRA4415N
40A
40A
16mm
2
/6AWG
16mm
2
/6AWG
CAUTION
The wire size is only for reference. Suppose there is a long distance between
the PV array, the controller, and the battery. In that case, larger wires can be
used to reduce the voltage drop and improve performance.