![Epever MSC-N Series Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/epever/msc-n-series/msc-n-series_user-manual_2417314024.webp)
20
3.3
Wire size
The wiring and installation methods must conform to the national and local electrical
code requirements.
PV wire size
The PV array output varies with the PV module's size, connection method, and
sunlight angle. The PV array's short circuit current(ISC) can calculate the minimum
PV wire size. Please refer to the value of ISC in the PV module specification. When
PV modules are connected in series, the total ISC equals any PV module's ISC.
When PV modules are connected in parallel, the total ISC equals the sum of all PV
modules' ISC. The ISC of the PV array must not exceed the controller's maximum PV
input current.
Please refer to the table below:
Model
Max. PV input
current
Max. PV wire size
*
MSC2210N
20A
6mm
2
/10AWG
MSC3210N
30A
10mm
2
/8AWG
MSC4210N
MSC4215N
40A
16mm
2
/6AWG
WARNING
The total voltage must not exceed the max PV open circuit voltage
when the PV modules are connected in series. PV open circuit
voltage 92V (MSC**10N), or 138V (MSC**15N) at 25
℃
environment temperature.
Battery wire size
The battery and load wire size must conform to the rated charge current; the
reference size as below:
Model
Rated charge current
Battery wire size
MSC2210N
20A
6mm
2
/10AWG
MSC3210N
30A
10mm
2
/8AWG
Содержание MSC-N Series