![Epever MSC-N Series Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/epever/msc-n-series/msc-n-series_user-manual_2417314023.webp)
19
According to the open-circuit voltage (VOC) and the maximum power point voltage
(VMPP) of the MPPT controller, the serial connection of PV modules suitable for
different controllers can be calculated. The below table is for reference only.
MSC2210N/MSC3210N/MSC4210N:
System
voltage
36cell
Voc
<
23V
48cell
Voc
<
31V
54cell
Voc
<
34V
60cell
Voc
<
38V
Max.
Best
Max.
Best
Max.
Best
Max.
Best
12V
4
2
2
1
2
1
2
1
24V
4
3
2
2
2
2
2
2
System
voltage
72cell
Voc
<
46V
96cell
Voc
<
62V
Thin-Film
Module
Voc
>
80V
Max.
Best
Max.
Best
12V
2
1
1
1
1
24V
2
1
1
1
1
NOTE:
The above parameters are calculated under standard test conditions (STC
(Standard Test Condition): Module Temperature 25
℃
, Air Mass1.5, Irradiance
1000W/m
2
.)
MSC4215N
System
voltage
36cell
Voc
<
23V
48cell
Voc
<
31V
54cell
Voc
<
34V
60cell
Voc
<
38V
Max.
Best
Max.
Best
Max.
Best
Max.
Best
12V
4
2
2
1
2
1
2
1
24V
6
3
4
2
4
2
3
2
System
voltage
72cell
Voc
<
46V
96cell
Voc
<
62V
Thin-Film
Module
Voc
>
80V
Max.
Best
Max.
Best
12V
2
1
1
1
1
24V
3
2
2
1
1
NOTE:
The above parameter values are calculated under standard test conditions
(STC (Standard Test Condition): Irradiance 1000W/m2, Module Temperature 25
℃
,
Air Mass1.5.)