Страница 2: ......

Страница 3: ...2 1 Designations of models 3 2 2 Accessories Included 4 2 3 Accessories Optional 4 3 Installation and wiring 5 3 1 Install the controller 5 3 2 Wiring 6 4 LCD display 8 5 Protection 10 6 Troubleshooti...

Страница 4: ...ngs carefully before installation No user serviceable component inside the controller DO NOT disassemble or attempt to repair the controller Avoid direct sunlight high temperatures and DO NOT install...

Страница 5: ...edded installation design High quality and low failure rate components ST IR to ensure the product lifetime 3 Stage intelligent PWM charging Bulk Boost Equalize and Float Battery type Sealed Gel Flood...

Страница 6: ...e sensor port 1 The controller will charge the battery at 25 as default and no temperature compensation when the temperature sensor is damaged 2 The port can detect accurate battery voltage a 2P 1 5mm...

Страница 7: ...on PC software The length of cable is 1 5m TheCC USB RS485 150U connects to the RS485 Port on the controller After the controller is connected with the eBox WIFI 01 through the standard Ethernet cable...

Страница 8: ...ion of installation location The controller shall be installed in a place with sufficient air flow through the radiators of the controller and a minimum clearance of 150 mm from the upper and lower ed...

Страница 9: ...ntroller 6 Install the control case 3 2 Wiring Step1 connect the battery CAUTION A fuse which current is 1 25 to 2 times the rated current of the controller must be installed on the battery side with...

Страница 10: ...onable arrester in the PV array input side Step3 Connect the Remote temperature sensor cable NOTE The controller will charge or discharge the battery at 25 as default and no temperature compensation w...

Страница 11: ...he SET button and hold 5s under the PV power interface and the value is flashing Step 2 Press the SET button to clear the generated energy 3 Switch the battery temperature unit Press the SET button an...

Страница 12: ...ware www epever com Solar Station Monitor www epever com ChargeController Sealed 1 Only Sealed Gel and Flooded via the LCD The battery type of User can be set via the PC software APP software and MT50...

Страница 13: ...ttery reverse polarity no damage will occur to the battery Correct the wiring error to resume normal operation Battery Overvoltage When the battery voltage reaches the overvoltage disconnect voltage i...

Страница 14: ...PV array disconnection Confirm that PV wire connections are correct and tight LCD is no display Min 8V will start up the controller Measure battery voltage with multi meter Min 8V can start up the con...

Страница 15: ...ate Coefficient 3mV 2V Default Charge Circuit Voltage Drop 0 21V The battery type of User can be set via the PC software APP software and MT50 Refer to table 1 Page 13 Environmental Parameters Storage...

Страница 16: ...V Discharging Limit Voltage 10 6V 10 6V 10 6V 9 17V Equalize Duration 120min 120min 0 180min Boost Duration 120min 120min 120min 10 180min 1 When the battery type is sealed gel flooded the adjusting r...

Страница 17: ...e environment PV or load current voltage or power exceeding the rated value of the controller The controller working temperature exceeds the range of working temperature User disassembles and attempts...

Страница 18: ...BEIJING EPSOLAR TECHNOLOGY CO LTD 15 9 Dimensions Any changes without prior notice V1 1...