background image

Dimensions - AS/ASHF/ASWP (Poppet design)

*  Depends on the pressure and design standards

0.2
0.7

1

1.5

3
4
5
6

10
12
15
20
24
28
32
50
60
80

100
130

10
15
20
24
32
50

3
4
5
6

10
15
20
25
28
35
37
55

1.6
2.2

4

5.3

9

12
14

16.5
26.5
30.5
36.5

44

51.5
58.5
73.5

102
135
169
203
233

33
37
56
66
94

132

*
*
*
*
*
*
*
*
*
*
*

AS 0.2
AS 0.7
AS 1
AS 1.5
AS 3
AS 4
AS 5
AS 6
AS 10
AS 12
AS 15
AS 20
AS 25
AS 28
AS 35
AS 55
AS 60
AS 80
AS 100
AS 130
ASHF 10
ASHF 15
ASHF 20
ASHF 25
ASHF 35
ASHF 55
ASWP 3
ASWP 4
ASWP 5
ASWP 6
ASWP 10
ASWP 15
ASWP 20
ASWP 25
ASWP 28
ASWP 35
ASWP 37
ASWP 55

330

 

360

330

330/

360

30/
48/
70/

120/

165

bar

Pre.

Max.

Model

 A

ø

D

C

ø

F

I

B

ø

E

H

A/F1

A/F2

kgs

ltrs

R

G

Wt.

Vol.

Dry

Gas

Fluid Port Connection (BSP)

250
280
300
355
540
405
465
530
570
600
670
880

1015
1140
1400
1915
1135
1395
1655
2045

620
800
930

1065
1450
1965

540
405
465
530
570
670
880

1015
1140
1400
1463
1915

22

47

60

60

60

47

47

60

40

52

65

101

137

137

52

65

101

51
90

114

168

223

356

226

*

*

*

20

25

55

55

55

25

25

55

26

36

53

77

97

97

36

53

97

---

11

11

11

*

*

*

140

140

140

140

140

140

140

24

32

70

90

90

32

32

70

23

32

50

70

90

90

50

50

70

1/2”

3/4”

1-1/4”

2”

2-1/2”

2-1/2”

1-1/4”

2”

—---

3/8”

3/8” - 1/2” - 3/4”

1/2” - 3/4” - 1”

1-1/4” - 1-1/2”

1” - 1-1/2” - 2”

1” - 1-1/2” - 2”

3/8” - 1/2” - 3/4”

1/2” - 3/4” - 1”

1-1/4” - 1-1/2”

AS/ASHF                                                                       ASWP

8

Fig.3b

Fig.3a

Dimensions

Содержание AS 0.2

Страница 1: ...he accumulator shell An inert gas nitrogen is filled into the bladder through a pressure valve to a pressure P The bladder expands filling 0 the entire volume V of the accumulator shell 0 When the sys...

Страница 2: ...ruction which is unique to EPE is moulded in a single piece thus obviating problems associated with seamed construction The gas valve is fitted in such a manner which allows it to be connected easily...

Страница 3: ...in Gas Precharge Pressure page 3 are valid although as the pressure and above all the velocity of the yield required increase there is the danger that in each cycle the bladder will knock against the...

Страница 4: ...For Food P standard B V E K N H F Y A 5 Shell material Carbon Steel Nickel Coated Carbon Steel Stainless Steel Rilsan Coated Carbon Steel C standard N X V 4 Max working pressure Bar For 0 2 AS For 0...

Страница 5: ...r variants 01 02 03 04 05 06 07 08 09 10 11 12 13 zz for S 1 1 16 12 1 5 8 12 1 7 8 12 21 22 23 for M M14x1 5 M16x1 5 M18x1 5 M22x1 5 M27x2 0 M32x1 5 M33x1 5 M40x1 5 M42x1 5 M45x1 5 M50x1 5 31 32 33 3...

Страница 6: ...g8 1 4 BSP M16x2 0 5 16 UNEF 7 8 UNF Gas Fill Valve Body Double Lock Military Valve 7 8 UNF Integral in 7 8 UNF Gas Valve M28x1 5 V standard X 0 1 2 3 4 8 9 M 9 Test Certification Factory Testing CE P...

Страница 7: ...2 NPTF Port Adapter with VS214 Gas Safety Valve set at xxx bar Adapter with VS224X Gas Safety Valve set at xxx bar Adapter with 1 4 BSP Needle Valve Adapter with 1 4 BSP Needle Valve in SS Adapter wi...

Страница 8: ...SWP 28 ASWP 35 ASWP 37 ASWP 55 330 360 330 330 360 30 48 70 120 165 bar Pre Max Model A D C F I B E H A F1 A F2 kgs ltrs R G Wt Vol Dry Gas Fluid Port Connection BSP 250 280 300 355 540 405 465 530 57...

Страница 9: ...XXX C13384 N10144 O10221 P10149 Q10226 S10228 161013 A12022 H12025 R12031 B10202 C10205 E10109 F10103 ASSY17 G10305 I10222 211030 K10227 L10223 M10217 05XXXX C13384 N10144 O10221 P10149 Q10226 S10228...

Страница 10: ...ASLVHF 475 ASLVHF 530 ASLVHF 575 Model A F1 A F2 32 70 70 80 120 11 14 56 56 140 140 74 88 130 I H 290 460 355 412 472 470 610 750 895 1025 1325 1392 1791 1132 1347 1688 1787 2112 2552 2805 2987 1222...

Страница 11: ...ASWD 4 6 ASWD 10 55 ASLV 150 575 ASLVHF 150 575 B10202 C10205 E10109 F10103 ASSY17 G10305 06XXXX C13384 I10446 212013 A12042 R12385 A12042 N A B10333 C10334 E10302 F10301 ASSY17 G10306 06XXXX C39XXX...

Страница 12: ...thout Gas Fill Valve Transfert Liquid Separator type 5 16 UNEF Vg8 1 4 BSP M16x2 0 5 16 UNEF 7 8 UNF Gas Fill Valve Body Double Lock Military Valve 7 8 UNF Integral in 7 8 UNF Gas Valve M28x1 5 V stan...

Страница 13: ...suitable for operating temperature 20 C to 85 C Other materials as indicated in ordering code also available THE GAS VALVE is of phosphated carbon steel in the following three versions S STANDARD Fitt...

Страница 14: ...ype M22 M22 B Type M50 Type M30 Type M22L Type M50L Type MU7 8U Type MU7 8V 5 8 UNF M30x1 5 M22x1 5 M22x1 5 M50x1 5 7 8 UNF Fill Valve Fill Valve Fill Valve Fill Valve Fill Valve M50x1 5 M50x1 5 M50x1...

Страница 15: ...fer Bladder Ordering Code Page 12 15 Type U7 8 Type U7 8V U7 8V B Type U7 8U Type U5 8 SL Type M22 SL Type M50 SL Type M22 ST Type M50 ST M50x1 5 M50x1 5 M22x1 5 M22x1 5 7 8 UNF 7 8 UNF Fill Valve 7 8...

Страница 16: ...for screw in fill valve M50x1 5 M Body for screw in fill valve long body 7 8 UNF M Body for screw in fill valve 7 8 UNF M with Integral Vg8 fill valve 7 8 UNF M with Integral Vg8 fill valve for Bosch...

Страница 17: ...BD 50 BD 75 360 360 360 bar Pre Max Model kgs ltrs Fig Wt Vol Dry Gas 8 9 10 Gas Bottle design Accumulator design Neck design Threaded design Ordering Code Dimensions Gas Bottles 1 2 3 4 5 6 BB 0 360...

Страница 18: ...ensions determined by the flow rate and operating pressure connects the various blocks The two ends have a BSP female thread or on request are flanged One of the ends is closed off with a plug or blin...

Страница 19: ...cal process must be carried out on the accumulator shell for the purpose of attaching fastenings CONNECTION adopters and flanges are available on request When fitting screws reducers or the safety and...

Страница 20: ...ng a pressure slightly above the required level Close the valve of nitrogen cylinder and disconnect the charging hose from the equipment Wait for the gas temperature stabilization Set the pressure by...

Страница 21: ...esired pressure Adjust by means of bleed valve remove the filling unit Use soapy water test for leaks Replace the valve cover and protection cap The accumulator is ready for use Standard equipment PC...

Страница 22: ...id port body into the vessel and remove the gasket and O Ring Fig D 4 Remove by bending the rubber coated retaining ring Fig D 5 Remove the fluid port body Fig D 6 Remove the nut holding the gas valve...

Страница 23: ...Charging page 20 and again tighten the gas valve nut Low Pressure Range ASWD Insert the bladder use a threaded tube M 12 x 1 5 Mount name plate and nut for the gas valve body Tighten the nut holding t...

Страница 24: ...ifferent fluid than those designed for Installation Before installation you must perform a visual check to verify that the accumulator has not suffered any damage during shipping handling Verify that...