- 10 - 

 

4

 Installation 

4.1 Safety 

 

DANGER!

 

Danger to life due to fire or explosion! 

Despite careful construction, electrical devices can cause fires. 
• Do not mount the inverter on flammable construction materials. 
• Do not install the inverter in areas where highly flammable materials are 

stored. 

• Do not install inverters in areas with a risk of explosion.

 

 

 

CAUTION!

 

Risk of injury due to the heavy weight of the inverter.

 

Take the weight of the inverter into account for transport. 

• Select a suitable mounting location and mounting surface. 
• When mounting the rear panel, use fastening material suitable for the 

mounting surface. 

• Two people are needed to mount the inverter.

 

 

 

CAUTION!

 

Danger of burn injuries due to hot enclosure parts!

 

Mount the inverter in such a way that it cannot be touched   
inadvertently.

 

 

4.2 Selecting the mounting location 

Consider the following points when selecting where to install: 

¾

 

The protection level of this product is IP65, so it can be installed outdoors. 

¾

 

Vertical installation. 

¾

 

Do not install horizontally. 

¾

 

Select a well-ventilated location sheltered from direct sun radiation. Choose a 

location that allows unobstructed airflow around the inverter.   

¾

 

The operation will generate some noise (<50dB), so please install away from the 

people living space.     

¾

 

Mount on a solid surface. Ensure the installation place does not wobble.   

 

Содержание EPIG5K

Страница 1: ...EPIG5K...

Страница 2: ......

Страница 3: ...es a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTIO...

Страница 4: ...lease read this manual thoroughly This manual contains information about EPIG5K single phase grid connected inverter of transportation installation operation maintenance and troubleshooting 1 3 Validi...

Страница 5: ...t up and maintenance must be performed by qualified and trained personnel DANGER After disconnecting the inverter from distribution grid wait for 60 seconds for capacitors to discharge before servicin...

Страница 6: ...rid connected system PV grid connected system consists of PV modules grid connected inverters metering device and power distribution system Figure 1 The solar energy is converted into DC current by PV...

Страница 7: ...wer system into alternating current with the same frequency and phase with the grid The downstream LC filter has the purpose of equaling the current Finally the current flows to the utility grid In or...

Страница 8: ...ial 3 Information Installation method as shown in the 5 5 1 of Information The PV input has one channel of MPPT which consists of three pairs of terminals so there can be max three PV strings connecti...

Страница 9: ...and installation 3 4 Technical data Type Specification 3 Input C D V 0 0 4 e g a t l o v C D l a n i m o N V 0 5 1 e g n a r e g a t l o v g n i t a r e p O 500V 0 2 5 e g a t l o v t u p n i V P x a...

Страница 10: ...c 1min Efficiency Max efficiency 97 5 Euro efficiency 96 5 General Requirements Standby consumption 12w Night consumption 0W Grid connected method Direct connect transformerless Ingress protection IP6...

Страница 11: ...Euro Others Items Specification Remarks Radiation noise CISPR22 Class A Conducted noise CISPR22 Class A AC short circuit protection Yes current limited Lightning resistant 1 2uS X 50uS 5kV DC AC to gr...

Страница 12: ...tening material suitable for the mounting surface Two people are needed to mount the inverter CAUTION Danger of burn injuries due to hot enclosure parts Mount the inverter in such a way that it cannot...

Страница 13: ...ent clearance between the individual inverters so that the cooling air from the adjacent inverter is not drawn in NOTICE Ambient temperature range shall be 20 C to 50 C It will affect the power output...

Страница 14: ...ct the AC and DC sides from all power sources and secure them against being inadvertently switched back on WARNING Always respect the nominal ratings of voltage and current specified in section 4 Tech...

Страница 15: ...g capacity can reach more than 1kA B PV arrays There are three pairs of input terminals in one MPPT channel for the inverter The allowable maximum open circuit voltage of PV arrays is 520V And the all...

Страница 16: ...DC Input 2 DC Input 3 L N EA5KLPV 10 10 10 10 10 10 10 10 There are three channels of DC input which can connect three PV strings The red is and the black is There is one channel of AC output the red...

Страница 17: ...ion cable of one PV array string for correct polarity and that the maximum input open circuit voltage does not exceed 520V Step 4 Measure DC voltage between positive terminal of the PV string and Eart...

Страница 18: ...d Do not insert the sealing plus into the DC inputs on the inverter Insert the DC plug connectors with sealing plugs into the corresponding DC inputs on the inverter 5 5 Connecting inverter to AC grid...

Страница 19: ...at the downside of the machine Step 2 Insert stripped AC cables of appropriate size into the cable glands Fix the phase cables into corresponding terminals with screwdriver according to marks Fix gro...

Страница 20: ...er Step 4 Tighten the cable gland in clockwise direction Pluggable AC output terminal installation method NOTICE The following installation method is only applicable to the series of special 3 Externa...

Страница 21: ...1 L Wire red 3 N Wire black PE Wire yellow green Attention Please ensure the corresponding relationship between polarity the core cable and the holes of the terminal is the correct Step 2 Screw these...

Страница 22: ...AC Output Wring Step 2 Make sure that AC and DC circuit breaker are disconnected Step 3 Connect L N to AC circuit breaker Plug AC connector to corresponding AC terminals Screw AC cables to AC circuit...

Страница 23: ...itoring system 6 Switch on and off 6 1 Switch on 1 Finish the installation of the PV array AC grid and the inverter according to the introduction before 2 Before switch on checking whether AC voltage...

Страница 24: ...Troubleshooting 7 1 Troubleshooting of the LED indicator Type of fault Troubleshooting LED indicators and LCD cannot be lit 1 Disconnect AC circuit breaker 2 Disconnect DC circuit breaker 3 Check the...

Страница 25: ...max or if local grid voltage is under the lower limit value of Vgrid min please contact your local electricity company to adjust the grid voltage 5 If the fault still exists please contact RPH UV Unde...

Страница 26: ...and this malfunction still occurs in the LCD screen please contact SYSCOM EPCOM MO FAULT There is a fault in the module of the inverter If this malfunction occurs the reasons are very complicated 1 D...

Страница 27: ...isplays the main running parameter including input voltage input current input power grid voltage grid current grid power and frequency After 5 minutes if there is no operation the LCD interface will...

Страница 28: ...elect HISTORY 4 Press ENTER into the History menu 5 Fault history including present fault information and history fault information 6 The exact fault as below DC over voltage AC low voltage frequency...

Страница 29: ...ect password the history information will be cleared please confirm it before the operation 8 2 3 POWER ON OFF 1 Enter the default main menu interface 2 Press ENTER into the control main menu 3 Select...

Страница 30: ...date is 2011 06 07 time is 15 23 11 so the code is 060715 6 press ENTER 7 Enter the parameter setting interface you can set the language time communication mode protect parameter code and so on 8 Sele...

Страница 31: ...nd fault information will be cleared and return to the parameter set interface so please think carefully to use the function of returning to the factory value 14 Press ENTER to select the data use the...

Страница 32: ...duct s type and software version 9 Appendix 9 1 Packaging list Check the packaging list for completeness and for any visible external damage Contact your dealer if anything is damaged or missing No it...

Страница 33: ...of the following z Improper or inappropriate use or install of the product z Installing or operating the product in an unintended environment z Installing or operating the product when ignoring relev...

Отзывы: