EN-32
Installation and Operating Instructions - EOS Zeus HD / Zeus L HD
Electrical installation
EN
6
Feed the connecting cable (
D
) through the rounded protrusions (
E
) at
the end of the air inlets to the outside.
7
Guide the connecting cable (
D
) from the cabin to the relay box and pow-
er extension unit.
Route the cable loop with sufficient cable length outside the heater
to simplify installation and maintenance.
8
CAUTION! Ensure that the units have no power.
Connect the connecting cable, see:
a)
4.2.1 Terminal diagram 20 kW–36 kW,
4.3 Heating period limitation
The heating period limitation is set either on the control panel or the relay
box circuit board, depending on the control unit used.
The settings are described in the installation and operating instructions for
the control units.
Heating period limitation functions
All sauna heaters, except for those installed in public saunas, and which
must be operated under the supervision of personnel, must be equipped
with a timer that complies with IEC and EN standards. This timer fully dis-
connects the sauna heater from the power supply for safety reasons. It is
typically integrated in the sauna control units.
The operation time of a public sauna must be limited so that the heat-
ing elements are without power for a minimum of 6 consecutive hours
within a 24-hour period.
Units used in private saunas must be limited to an operating time of
6 hours, and an automatic restart is not permitted.