background image

18

GB

place any herbs into the vaporizer holder 
for essences/herbs. 

Risk of fi re!

• 

 Never add more essences or volatile 

oils than advised on the packaging. Nev-
er  use  alcohol  or  undiluted  concentrates. 
Caution! 

Fire hazard!

Caution!

Dear Customer, 
In  compliance  with  the  valid  regulations, 
only certifi ed electricians may connect the 
sauna heater and the sauna control system 
to  the  mains  power  supply.  Please  note 
that you must provide a copy of the invoice 
from the electrical company who installed 
the sauna in case of a warranty claim.

Electrical connection 

Using  the  above-mentioned  wiring  diagram 
and the information on the wiring circuit ad-
hered  to  the  respective  control  system,  your 
electrician will be able to connect the system 
without further instructions.

Please note that, for safety reasons, power ca-
bles may not be laid visibly on the interior walls 
of  the  cabin.  Most  sauna  cabins  have  empty 
ducts fi tted into the wall element with the air 
intake.
If  no  empty  ducts  are  available  in  your  cabin, 
drill  a  suffi

  ciently  sized  hole  in  the  cabin  wall 

directly next to the place where the cable exits 
the  sauna  heater  and  guide  this  cable  outside 
through the hole to the control unit. The cable, 
and  all  other  connecting  cables  (mains  power 
cables  and  cabin  lighting),  should  be  installed 
in installation ducts or also be protected against 
damage on the outside of the cabin e.g. by lay-
ing them in installation pipes or attaching wood 
cover strips.
The sauna heater may only be used in combina-
tion with a protective cover or S-guard system 
if operated by remote control*

*Remote  control  =  Setting,  control  and/or  regulation  of 
the device by means of commands entered when the de-
vice is out of sight. Telecommunication, sound technology 
or bus systems can be used.

Содержание Thermo-Tec S

Страница 1: ...1 D MADE IN GERMANY IP x4 Thermo Tec S Druck Nr 29343829en 28 12 GB Assembly and operating instruction...

Страница 2: ...otes 4 Electrical connection 5 Example of a properly connected sauna system 6 Installation 7 Technical data 7 Minimum clearances 7 Sauna stones 9 Maintenance and care 9 Service Address 11 Guarantee 11...

Страница 3: ...pped the goods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please...

Страница 4: ...resin untreatedmaterials e g spruce Only a sauna heater with the appropriate power output may be installed in the sau na cabin Please provide air intake and vent ope nings in each sauna cabin The air...

Страница 5: ...that the vertical clearance be tween the sauna heater upper edge and the sauna ceiling is maintained Please see also the dimensions diagram for the clearance between the lower edge of the sauna heater...

Страница 6: ...y reasons power ca bles may not be laid visibly on the interior walls of the cabin Most sauna cabins have empty ducts fitted into the wall element with the air intake If no empty ducts are available i...

Страница 7: ...1500W 9 kW Capacity acc DIN Electrical Connection Fuse control unit in A For cabin size Minimum dimensions of air intake and exhaust vents Connecting cable main control unit in mm Connecting cable con...

Страница 8: ...5 4 ea particle board screws 1 set of sauna stones separately in cloth bag The sauna heating unit is intended only for a supply voltage of 400 V AC 3N The minimum height of the sauna cabin must be 1...

Страница 9: ...Illust 4 4 Hook the sauna heating unit into the wall mounting using the mounting slots on the rear wall and place against the spacer Illust 7 Terminal box spacer Illust 4 Anschlussklemme Lock nut Cab...

Страница 10: ...tones will re heat suffici ently again Never add more essences or volatile oils than advised on the pa ckaging Never use alcohol or un diluted concentrates Caution Fire hazard All sauna heating units...

Страница 11: ...ical units will be protected by this ELCB Under current manufacturing technology it is not reasonable to use heating elements for sau na heaters which do not collect moisture from the surrounding air...

Страница 12: ...nd model name with detailed description of the fault This guarantee covers defective parts and la bour but not the defects caused by wear and tear In case of complaint please return the equip ment in...

Страница 13: ...dual case and try for immedi ate and customer friend ly solution For economic returns wi thin Germany you will get an RMA number from the manufacturer All returns have to be in the original packing of...

Отзывы: