34
EN
Fault
: No descaler liquid (pilot lamp flashing 3 times)
Remedy:
Replenish the descaler liquid container. Make sure to use the suitable type of descaler.
Check the level probe for lose connection and verify it is connected properly.
General fault
: Overheating limiter fuses releases occasionally.
Remedy
: Increase the water filling level in the water tank by pulling the water level probe up to1
- 2 cm up.
ATTENTION! If the water level in the tank is too high the steam generator may “spit” hot water
through the steam outlet at the beginning of steam generation. Risk of scalding!
Fault
: Steam outlet spits hot water. Risk of scalding!
Remedy:
Reduce the water level in the water tank slightly by pushing the level probe down 1 - 2
cm.
ATTENTION! By too low water level there is risk of overheating in the area of the upper heat-
ing element and the overheating safety fuse (thermofuse) may release
Fault
: Steam generator does not produce steam (no heating), pilot lamp illuminates continu-
ously, not error messages.
Remedy:
Thermofuse may have released due to overheating in the watertank. Reset the thermo-
fuse by pushing the reset button on the bottom panel of the generator (see page 12). Check for
possible reasons of overheating.
13. Disposal
The electric devices which are no longer required shall be recycled as per EU guideline 2002/96/EG
or as per applicable national laws. Do not dispose of with the household garbage.