Operation
Opening the housing cover
1
Switch off the steam request at the control unit.
2
Disconnect the mains connection and switch off the water supply.
3
Unscrew the eight (8) retaining screws in the left side panel of the hous-
ing and remove the panel.
Removing the left side panel
Unscrewing and removing the immersion heaters
1
DANGER! Check that the power supply has been disconnected.
Remove the wiring from the immersion heaters.
2
Remove the wiring’s flat plug from the heaters.
Tip: To simplify reinstallation, mark the plug before removing it.
3
Unscrew the heaters at the metal bushes.
Use the SW66 hexagon key.
4
Clean or replace the heaters.
Replace defective heaters with original spare parts only.
5
Check the vaporiser tank for limescale and clean manually, as needed.