34
Installation and Operating Instructions - SteamAttrac
EN Mounting
3.2.2
Connecting the water supply line and drain outlet
Necessary steps
Connecting the cold water supply line,
Ha tools:
0.5 m tube with screw, 3/4” female thread
SW46 spanner
Ha tools to mount to the water supply
Ha tools to mount to the drain pipe
NOTICE
Contamination of and damage to the vaporiser tank
Traditional PVC garden hoses contain plasticisers that can cause a
thick layer of foam to form above the water line in the vaporiser
tank.
The water level sensor cannot differentiate foam from water, and
the actual water level lies significantly below the layer of foam.
This could cause overheating and an emergency shutdown, which
can lead to various types of damage, e.g. failure of the tempera-
ture limiter.
Use hoses that are PVC-free for the cold water supply.