REVELATION
Ⅱ
REVELATION
Ⅱ
Alkaline Water Ionizer
Alkaline Water Ionizer
■
Computer Controlled Electrolysis System
The Revelation
Ⅱ
calculates the water flow and quality of the source water
and automatically adjusts ionization to create the best ionized water.
■
One-touch Automatic Water Flow Control
Just press the water “on” button to release water through the Revelation
Ⅱ
,
then press it again to stop the water flow.
■
Voice Announcements
The Revelation
Ⅱ
announces the ionization level, self-cleaning process, and
many other important functions.
■
Filter Replacement Microflow Sensor System
The Microflow sensors inside the Revelation
Ⅱ
filters communicate
with the Revelation
Ⅱ
so that it can accurately tell you when to change
your filters.
Revelation
Ⅱ
Product Features
The Revelation
Ⅱ
offers a combination of EOS's highly advanced technology,
elegant design, and advanced computer system, providing ease of operation and
excellent performance.
Revelation
Ⅱ
Product Features
■
9 Platinum and Titanium Plates
Manufactured by the top metal producer of Japan, EOS platinum and
titanium plates are of the highest quality and produce abundant hydrogen for
maximum health benefits. The plates come with a lifetime warranty.
■
Turbo Function
The TURBO Function allows users to create the strongest alkaline and acid
water simultaneously with just the push of a button. Perfect for cooking,
cleaning, sterilizing and disinfecting.
5
Troubleshooting: Problems and Solutions
40
Problem
Causes
Solution
My water tastes funny.
Filter is at the end of its life. Or,
there's something in your tap
water that requires additional
filtration (like sulphur).
Change the filter. If taste persists, get a
water test done.
Water isn't coming out
of my
REVELATION
Ⅱ
or
the water flow is
weak.
The supply hose may be bent. The
water diverter valve may need to
be opened more. The water “on”
button may need to be pressed, or
water pressure is too weak.
Check all hoses. Check your water
diverter valve to make sure flow is
strong. Make sure you have pressed
the “on” button. Check your home
water pressure.
I've tested the pH of
the REVELATION
Ⅱ
water and it doesn't
test right.
Tap water mineral content is too
low or water is hard. Water flow
through REVELATION
Ⅱ
is too
high. “Mode” settings may be
too low for your water.
Check to see if your tap water has a
good supply of minerals, flow rate is
between 2 and 2.5 liters per minute,
and adust your mode settings higher or
lower accordingly.
My REVELATION
Ⅱ
shuts down while I'm
still using it.
The REVELATION
Ⅱ
is
overheating. The
REVELATION
Ⅱ
has been running
for more than five minutes
continuously. The water pressure
on the REVELATION
Ⅱ
may be
too strong.
Let the REVELATION
Ⅱ
rest for a few
minutes. Check to make sure your
water flow rate is between 2 and 2.5
liters per minute.
There is a water leak
from my
REVELATION
Ⅱ
.
One of the filters is improperly
seated or the “O” ring is missing.
There is something wrong with
the REVELATION
Ⅱ
internally.
Check both the #1 and #2 filter for
proper installation. If the leak is
coming from under the unit near the
electrical, unplug immediately and call
your dealer.
There is a white
substance left over on
the bottom of my
glass!
It's just minerals from your tap
water because water ionization
reduces water and concentrates
the minerals.
Drink it! The minerals aren't harmful.
Clean the glass with soap.
My REVELATION
Ⅱ
will only dispense
“pure” water.
The water flow rate may be
greater than 3.5 liters per minute
or less than 1 liter per minute.
Adjust the water flow to between 2 and
2.5 liters per minute