31
EN
Connection example for 230V 1N AC
7,5 kW = 3x 1000 W + 3x 1500 W
9,0 kW = 6x 1500 W
Saunaofen /
sauna heater
poêle de sauna / печь сауны
max. 7,5 kW
230 V AC
PE (Gr)
L
N
6 mm² / 35 A
A1
A2
A3
B1
B2
B3
M
reset
A1
A1
B1
B
A
A
L1 L2 L3
N
N
PE
Thermostat
Sicherheits
temperaturbegrenzer
Zeitschaltuhr
timer
Thermostat
overheat safty
shutdown device
N
Power output
Electrical connection
Fuse protection
Connecting cable
mains - heater
7,5 kW
230 V 1N AC 50 Hz
1 x 35 A
3 x 6 mm²
9,0 kW
1 x 35 A
3 x 6 mm²
All cross sections of a line are minimum diameters in mm² (Copper line).
All cross sections are given for 230V 1N power supply!
Specifications for 230V 1N connection
By 230V 1N connection the 3-pole
copper bridge must be fitted on
the U/V/W terminals. This bridge is
included in the delivery scope.
Содержание Edge Control