30
EN
To be connected by a qualified electrician:
Drill an approx. 10 mm hole in the cabin wall near the entry area of the stove‘s connecting cable.
Feed the connecting cable through the borehole to the outside and connect to the power supply
in a distribution box suitable for wet rooms.
Please observe the wiring diagram and the regulations of the local power supplier (TAB 2000) and
the VDE.
Caution!
An adequate fuse and a mains circuit breaker must be installed in the heater‘s
power supply line on site.
Connection example for 400V 3N AC
Power acc. DIN
Electrical connection
Fuse protection
Connecting cable
main - heater
7,5 kW
400 V 3N AC 50 Hz
3 x 16 A
5 x 1,5 mm²
9,0 kW
All cross sections of a line are minimum diameters in mm² (Copper line).
A1
A2
A3
B1
B2
B3
M
Netz / Mains / Réseau / Сеть
400V 3N AC
reset
5 x 1,5²
max. 10 m
A1
A1
B1
B
A
A
L1 L2 L3
N
5 x 2,5²
Leuchte
Absicher
ung
Hauptschalt
er
Ver
teiler
dose
bauseitige Installation
L1 L2 L3
N
N
PE
1000 W
1500 W
1500 W
1500 W
1000 W
1000 W
7,5 kW
9,0 kW
Thermostat
Sicherheits
temperaturbegrenzer
Zeitschaltuhr
timer
Thermostat
overheat safty
shutdown device
N
1500 W
1500 W
1500 W
1500 W
1500 W
1500 W
Caution!
Make sure to connect the neutral wire N.
Specifications for default connection 400V 3N AC
Содержание Edge Control