8
EN
Technical data
Voltage (power supply)
400 V 3 N 50 Hz AC
Switch output
max. 9 kW resistive load (AC1 mode).
Heating time limit:
12 h
Display
LCD display 40 x 22 mm, graphic
Dimensions (HxWxD)
220 x 250 x 67 mm
Protection type
IPx4 acc. to EN 60529 splashwater protection
Temperature control range
30 to 70 °C
Sensor system (temperature)
KTY-sensor with safety temperature limiter 139 °C
Control characteristic
Two-point control with fixed hysteresis of 3K. For control via
the stove sensor offset of 7K to compensate the higher tem-
peratures directly below the cabin ceiling
Light
max. 100 W
Ambient temperatures
-10 °C to +40 °C
Storage temperature
-20 °C to +70 °C
Temperature display temperature
sensor
Current value on the sensor minus 7K to compensate the
higher temperatures directly below the cabin ceiling