14
GB
Connecting the sauna heater (max. 9 kW)
Connection of sauna heater > 9 kW
max. 100 W
400 V 3 N AC 50 Hz
max. 100 W
X1
ECON
P max. 9 kW
U
V
W
N
L1 L2
L3
N
V1 N S1
142°C
KTY 10/5
Sensor
Limiter
weiß / white
rot / red
X2
N L
L N
WM
WB N
120°
max. 3 kW
max. 100 W
400 V 3 N AC 50 Hz
max. 100 W
X1
ECON
U
V
W
N
L1 L2
L3
N
V1 N S1
142°C
KTY 10/5
Sensor
Limiter
weiß / white
rot / red
X2
N L
L N
WM
WB N
P max. 9 kW
400 V 3 N AC 50 Hz
LSG
120°
max. 3 kW
Warning: Always connect the neutral conductor of the sauna oven. During steam
operation, one phase of the oven is shut down; therefore the heating load is no longer
symmetrical. The result is that the neutral wire is no longer current-free.