12
GB
Electrical connection
The electrical connection may only be
done by a certifi ed electrician in compli-
ance with the guidelines of the local utility
company and the VDE.
In general, there may be only one
fi xed con-
nection to the network; therefore equipment
should be provided that makes it possible
to disconnect the system with all poles from
the network with a contact opening width of
minimum 3 mm.
All electrical installations and all connection
lines that are installed inside the cabin must
be suitable for an ambient temperature of at
least 170 °C.
.The power supply line is run to the load con-
trol unit and connected to the power input
terminals.
Install the sauna heater and the vaporizer in
front of the air intake according to the manu-
facturer’s installation instructions.
Run the silicone line through the ductwork
to the power unit and connect it to the ap-
propriate terminals as directed in the wiring
diagram.
Note:
In case there is no ductwork available
drill a hole next to the air intake opening and
run the heater line through this hole to the
outside and to the appropriate terminals in
the control unit. The silicone line must be
buried to protect it from outside infl uences.
Therefore, use a suitable cable-duct or a
PVC-pipe through which you can run the line
up to the power unit.
Connecting the
sauna heater
The sauna lamp must be weatherproof pro-
tected (IPx4) and resistant to the ambient tem-
perature. The sauna lamp may be installed
at any location but never in the vicinity of the
rising hot air of the heater.
Connecting the sauna lamp
To connect the vaporizer, use silicone con-
necting lines 4 x 1,5 mm² as well.
Warning: When connecting
the vaporizer make sure it is
correctly attached to the water bath
(WB) and low water shutoff (WM). If
you switch these connections, you dis-
able the water defi ciency function and
bypass the thermostat. As a result, the
vaporizer will overheat
.
Risk of fi re!
Connecting the vaporizer
The control unit can detect water defi cit if
there is a zero-potential feed at the WM-input.
Connecting a fan
The fan must be weatherproof protected
(IPx4) and resistant to the ambient tempera-
ture.
The fan can be mounted at any point, but
never near to rising hot air from the heater
and as far as possible from the installation
position of the IR lamp (may not be in the
direct beam).
LSG
Connecting a load switch
(LSG)
For details refer to the installation instructions
of the LSG.