Connection of sauna heaters up to 9 kW
Attention! Always connect the N
terminal of the sauna heater!
Connection of sauna heaters above 9 kW
A control lamp indicating active heating must be installed in the room or location of supervising
staff by commercial sauna cabins with disabled heating time limitation.
400 V 3 N AC 50 Hz
max. 100 W
X1
ECON
P max. 9 kW
U
V
W
N
L1 L2
L3
N
V1 N S1
142°C
KTY 10/5
Sensor
Limiter
weiß / white
rot / red
X2
N L
max. 100 W
max. 100 W
P max. 9 kW
400 V 3 N AC 50 Hz
LSG
400 V 3 N AC 50 Hz
max. 100 W
X1
ECON
U
V
W
N
L1
L2
L3
N
V1 N S1
N L
142°C
KTY 10/5
Sensor
Limiter
weiß / white
rot / red
X2
15
GB