background image

26

GB

Life - Guard

12:00

30° C

Temperature

12:00

20 

min

Life - Guard

MODE

In Stand-by

12:00

20 

min

Life - Guard

12:00

15 

min

Life - Guard

MODE

Here you can set after what time the sauna unit is switched off  and by pushing the 

MODE

 - button 

again you can restart the „Life - Guard“ time.

This setting can only be selected in Stand-by when the function „

Life - Guard

“ is activated. 

12:00

15 

min

Life - Guard

12:00

30° C

Temperature

15 s

12:00

30° C

Temperature

> 3 s

Содержание ECON D1

Страница 1: ...1 D IP x4 Made in Germany ECON D1 Druck Nr 29344711en 23 15 GB Installation and operating instruction sauna control unit...

Страница 2: ...or 10 Electrical connection 12 Connecting the sauna heater 12 Connecting the sauna lamp 12 Installation diagram 13 Terminal arrangement on the circuit board 13 Connecting the sauna heater 14 Operation...

Страница 3: ...Switching on the sauna unit with Life Guard 22 Individual settings 23 Cabin temperature 23 Auto Stop 24 Life Guard 25 Unit fuses 27 Error messages 28 The device switch Switch off 29 Service Address 30...

Страница 4: ...rature protection fuse Technical data Nominal voltage 400 V 3 N 50 Hz AC Switching capacity max 9 kW ohmic load AC1 operation Heating time limitation 6 h Display LCD display 40 x 22 mm alphanumeric wi...

Страница 5: ...ods Please note that you will only be able to achieve anoptimumsaunaclimateifthecabinwithitsair intake and ventilation the sauna heater and the control unit are aligned to each other Please observe th...

Страница 6: ...e the dimensions in the assem blyinstructions especiallywheninstalling the temperature sensor The temperature above the oven is critical for the temper ature setting The temperature can be held within...

Страница 7: ...ialist of an authorized electric shop We would like to draw your attention that in case of a warranty claim you are kindly requested to present a copy of the invoice of the executive electric shop Whe...

Страница 8: ...hole The control unit is hooked onto this screw Therefore leave the screw out by approx 3 mm Fig 3 2 3 Hook the control unit onto the 3 mm protru ding screw in the upper mounting hole Insert the supp...

Страница 9: ...east 3 5 cm deep according to the dimension in Fig 5 Insert the supplied rubber grommets into the openings at the rear wall of the housing and insert the connecting cables through these openings Place...

Страница 10: ...oven sensor in cabins up to 2 x 2m according to Illust 7 and 8 in larger cabins according to Illust 7 and 9 20 cm Fig 7 Housing Red Red Sensor circuit board Sensor white Limiter white Limiter Illust 1...

Страница 11: ...t the line for overtemperature protection must be checked for short circuits In order to do this disconnect one of the wires of the white ca ble in the sensor casing The respective error message appea...

Страница 12: ...nt of the air intake according to the manufacturer s installation in structions Run the silicone line through the ductwork to the power unit and connect it to the appropri ate terminals as directed in...

Страница 13: ...13 GB Installation diagram 3 5 4 5 400 V 3 N AC 50 Hz ECON X2 F2 F1 L1 L2 L3 N W V U N N L Terminal arrangement on the circuit board Plug for sensor connection...

Страница 14: ...cting the sauna heater 400 V 3 N AC 50 Hz max 100 W X1 ECON P max 9 kW U V W N L1 L2 L3 N 142 C KTY 10 5 Sensor Limiter wei white rot red X2 N L Warning Always connect the neutral conductor N of the s...

Страница 15: ...you can put your sauna unit into operation Over the following pages we will show you the options provided to you with the control The user interface Operating buttons Cabin lighting on off Heating on...

Страница 16: ...ing phase the thermometer fills up on the right side of the display Energy saving display 12 34 12 00 5 59 Auto stop Current time The clock symbol The light symbol when the light is switched on 12 00...

Страница 17: ...r change is made 12 00 30 C Temperature Modifiable parameter 12 00 30 C Temperature If no key is pressed for 15 s the unit switches back into the default display Changes made up to then are not saved...

Страница 18: ...ommissioning 12 00 DE GB NL PL I RU 12 00 0 00 0 00 Time of day 12 00 DE GB NL PL I RU 12 00 12 00 Time of day 12 00 12 00 Time of day 12 00 12 30 Time of day 12 00 Life Guard 3 s 3 s 3 s 12 00 12 30...

Страница 19: ...time 12 00 DE GB NL PL I RU 12 00 DE GB NL PL I RU 12 00 DE GB NL PL I RU 12 00 12 30 Time of day 3 s 12 00 12 30 Time of day 12 00 30 C Temperature MODE MODE MODE MODE 12 00 12 30 Time of day 12 00 1...

Страница 20: ...ort time e g 20 minutes after which the sauna unit is switched off except for the cabin lighting Af ter this time has elapsed the unit can be MODE switched on again by pushing the button for the set t...

Страница 21: ...em can still be switched off in operation 12 00 30 C Temperature 3 s 12 00 30 C Temperature 12 00 30 C Temperature Activate Stand by Operation Deactivate 12 00 30 C Temperature 3 s 12 00 30 C Temperat...

Страница 22: ...nction Life Guard 12 00 14 min Life Guard MODE After expiration of the Life Guard time the sauna heater is switched off and the set Life Guard time blinks Restart MODE or switch off the system 3 s 12...

Страница 23: ...Temperature MODE 12 00 85 C Temperature Setting range Finnish mode 30 115 C 12 00 85 C Temperature 3 s 12 00 30 C Temperature MODE Hereafter we are showing you options that allow you to adjust the co...

Страница 24: ...xpired The time is adjustable from 0 01 to 6 00 hours 12 00 30 C Temperature 12 00 6 00 Auto stop MODE In Stand by In operation 12 00 6 00 Auto stop 12 00 30 C Temperature 12 00 6 00 Auto stop 12 00 3...

Страница 25: ...25 GB 12 00 3 30 Auto stop 3 s MODE 12 00 3 30 Auto stop 15 s 3 s MODE 12 00 30 C Temperature 3 s 12 00 30 C Temperature 12 00 3 30 Auto stop 12 00 30 C Temperature...

Страница 26: ...ife Guard MODE Here you can set after what time the sauna unit is switched off and by pushing the MODE button again you can restart the Life Guard time This setting can only be selected in Stand by wh...

Страница 27: ...1 L1 L2 L3 N W V U N N L F1 F2 Unit fuses F1 T 2A Fuse electronics primary and light and fan F2 T 315 mA Fuse of the electronics secondary Load board D1 Control board Only allow a specialist to carry...

Страница 28: ...erature sensor PTC is faulty or the line to the temperature sensor has a short circuit interrupted limiter circuit The temperature fuse 142 C has triggered or the line to the temperature fuse is inter...

Страница 29: ...s using this switch To turn the light on in the cabin while the unit is still disconnected push the left side of the ro cker to the second latch switch setting II Tomaketheunitreadyforoperation switch...

Страница 30: ...el name with detailed description of the fault This guarantee covers defective parts and labour but not the defects caused by wear and tear In case of complaint please return the equip ment in its ori...

Страница 31: ...p ping of individually packed goods pallet We expressly point out that our packaging is not suitable for individual shipments via parcel post The manufacturer shall accept no liability for damage incu...

Отзывы: