25
GB
E
E
Control unit
switch
= unit swit-
ched on
=unit swit-
ched off
= light swit-
ched on
H- - -
In case of breakdown, press the control unit
switch on the left part of the rocker to the
fi rst position (switch position 0). The unit is
now completely switched off.
The control unit switch (Switch-
off)
The control unit switch can be found on the
top end of the unit. Using this
switch, you can isolate the electronics from
the mains supply in case of a breakdown.
Please note that operating the control unit
switch returns all settings to the factory
settings.
In order to switch on the light in the sauna
when the unit is switched off, press on the
left part of the rocker to the second position
(switch position II).
In order to put the unit back into operation,
switch back to the starting position (switch
position I).
Troubleshooting / error messages
Display / sym-
ptom
Cause
Remedy
See Section 3.2.1 in these operating in-
structions.
Interruption or short
circuit in sensor cir-
cuit
Check KTY sensor (approx. 2 kOhm at 20°
C). Check wire (red) and connections for
interruption or short circuit.
Interruption in limiter
circuit
Check continuity on safety temperature limi-
ter. Check wires (white) and connections
Control unit switch
switched off
Switch on control unit switch
Mains fault
Check on-site fuses and main switch
Lack of water in va-
poriser
Unit not working
Display dark
Содержание ECON 45H2