8
EN
Assembly
Minimum clearances
• When assembling the sauna heater, make
sure that the horizontal (side) clearance bet-
ween the heater and cabin wall is at least 4
cm (fig. 2).
Cabin wall
Protective grating for heater
• The distance from the heater grid and the
bench to other inflammable materials near
the heater must be at least 4 cm. The heater
grid must be more or less the same height as
the front of the heater.
• Complete the connections as shown in the
circuit plan. A circuit diagram is attached in
the mains connection area.
• Connect the unit to the control unit.
Make certain that you have complied with
the local electricity board and the VDE re-
commendations.
• Place the lid on the connection box. Use 4
metal screws for this.
Scope of delivery
The following are included in the scope of de-
livery:
• 1 Sauna heater
• 1 Evaporator cover with herb bowl and filter insert
• 1 safety bracket with 2 corrugated-head screws
• 1 enclosed floor equalisation profile set
• 1 set of sauna rocks
Fig. 2
4 cm
Fig. 3
• Push the safety bracket under the heater co-
ver in the middle of the reverse side and affix
to the cabin wall using the two spax screws
(see fig. 3)
Safety bracket
Spax screws
Cabin wall
4 cm
4 cm
40 cm
39,5 cm
4 cm
4 cm
• The minimum interior height of the sauna ca-
bin is 1.90 m (Fig 1).
Fig. 1
Bi-O
Cubo
min. 190 cm
95 cm
max. 11,5 cm
Cabin ceiling
Ventilation
required in the
lower area