14
Call 1300 369 273
www.enware.com.au
BOTTLE FILLER - SERVICING SPRING ACTION SBA
It is recommended that the spring action be periodically serviced. As a guide, every 6 months
the spindle should be cleaned and re-greased, and the push button and other components
checked for tightness. The servicing interval will vary depending on the frequency of use of
the product, water quality and the general environment.
If the components inside the SBA are worn or damaged, replace the SBA or use the service
kit to replace components.
REMOVING THE TOP ASSEMBLY TO ACCESS SBA, CLEANING & REFITTING
1. Using a 3/32” or 2.5mm Allen key undo the grub screw located near the hex of the dome.
2. Unscrew the dome from the SBA.
3. Remove any grease or scale build up in the dome and the top assembly components. Use
a diluted solution of CLR for cleaning if necessary.
CLEANING AND LUBRICATING THE SPINDLE
The spring action can be maintained by simply cleaning and lubricating the spindle (piston)
using a silicon- based lubricant approved for potable water. This can be done without turning
off the water supply.
1. Pull out the piston (the top part) of the SBA and wipe off any excess grease. SEE IMAGE
NEXT PAGE
2. Clean the two small o-rings. Replace them if necessary, and re-grease them.
3. Push the piston back into the SBA.
REPLACING THE SBA
1. Shut off water supply and remove the top assembly.
2. Use a suitable spanner (26mm) and unscrew the SBA from the tap body. Make sure the
seal o-ring is not left on the seat of the body and the old red fibre washer is also removed.
3. Replace with a new SBA.
4. Turn on water supply.
5. Depress the piston to start water flow. Release the piston to stop the flow and check for
leakage. If a leak is present refer to Troubleshooting to identify cause of leakage and rectify
before proceeding.