www.enware.com.au
Call 1300 369 27
3
IMPORTANT - This must be read before proceeding with installation
1. Enware products are to be installed in accordance with the Plumbing Code of Australia
(PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may
void the product and performance warranty provisions. Reference should also be made
to the ABCB and Local Government regulations when considering the choice of, and the
installation of these products.
2. Electrical installation must be in accordance with AS/NZS3000-2018.
3. Water connection to the water cooler should be made through an approved Non-Return
Isolating Valve/ Stop Tap and installed in an accessible position.
* Note: Non-Return Isolating Valves/Stop Taps are not supplied with this product.
4. Water supply pressure must not exceed 500kPa. It is recommended that an approved
500kPa Pressure Reduction Valve be installed with all water chillers to safe-guard against
pressure surges that may occur in the supply lines, especially at night.
5. For use with potable water only.
NOTE: Enware Australia advises:
1. Due to ongoing Research and Development, specifications may change without notice.
2. Component specifications may change on some export models.
installation compliance
technical data
Chilled Water Production
up to 18 Litres/hour
Recommended Water
Supply Pressure
50-500 kPa
(Use of pressure reduction valve is recommended if inlet pressure
may exceed 500 kPa)
Power Supply
240V / 50 Hz
Power Connection
3 pin 10 A plug with 2m lead
IP Rating
IP23
Water Inlet Connection
1/2” BSP male
Water Drain Connection
40mm DWV PVC
Storage Tank
4 Litres
Compressor Size
362 W
Condensor
Wire tube
Refrigerant
R134A
Climate Condition
SN.N *
Net Weight
30kg
Bottle Filler Flow Rate
2 L/min - 7 L/min
adjustable
* Suitable for use in ambient temperatures of 10°C to 32°C