Страница 2: ...oning the energiSava 210 6 Operating the energiSava 210 CONTENTS The following items are included 1 1 x energiSava 210 2 1 x remote control 3 1 x wall bracket 4 2 x drain ducts 5 1 x drain connector 6...

Страница 3: ...use Normal wear of components Failure to follow the instructions in this manual concerning safety use and installation The use of parts not supplied by Envirovent 1 3 Safety General health and safety...

Страница 4: ...performance can reach 95 Condensation forms during the heat exchange process and is recovered in the condensate tray which must be connected to a waste water drain The energiSava 210 is equipped with...

Страница 5: ...d air Extract air from the building Connected to the extract duct from the property To avoid thermal losses and optimise the performance of the installation it is recommended to use insulated ducts fo...

Страница 6: ...2 3 Dimensional characteristics 2 3 a Central Weight 15Kg 2 3 b Remote control 6...

Страница 7: ...orrectly installed In areas where temperatures are regularly negative or can drop below 10 C it is advisable to install a preheating battery It is advisable to install the energiSava 210 in the heated...

Страница 8: ...is configuration the condensation is generated on the other side of the heat exchanger So the energiSava 210 is equipped with a dual condensate drain system Installing and connecting the drain kit for...

Страница 9: ...kitchen Toilets Living room Bedrooms Or CPR or CT 125 BDO or BOAP 125 BDO or TPM 80 If using insulated flexible ducting it is imperative to fully stretch it Or Air intake PAQS125 BDO or TPM 80 RD 80...

Страница 10: ...r CT 125 BDO or BOAP 125 BDO or TPM 80 RD80 BDO 80 RD80 Air intake PAF 125 Or Or Air intake PAQS125 SAMPLE DISTRIBUTION ASSEMBLY Living Room Bedrooms If using insulated flexible duct it is imperative...

Страница 11: ...x Power 80 W Maximum ambient temperature 50 C Maximum flow temperature 45 C Power wire type H05VV F 3G0 75 Connection box Electrical panel Control wire type H05VV F 4G0 25 Electrical panel Connection...

Страница 12: ...tor Power supply motor Extract fan Power supply motor Supply fan energiSava 210 power supply Remote control Pre heating and post heating batteries External sensor 0 10V Programming and reprogramming c...

Страница 13: ...tion of the house depending on the number of main rooms living room dining room bedroom office etc and the number of toilets and bathrooms Open the unit and set each potentiometer as shown in the tabl...

Страница 14: ...m Of course after the installation the extract air is dusty and not representative of a normal conditions During the second filter check if you notice that the filters are clean you can increase the t...

Страница 15: ...y Follow the recommendations below Ensure that all doors and windows are closed Light a fire in the chimney Adjust the imbalanced airflow with the potentiometer until there is a good draught of the ch...

Страница 16: ...kitchen green LED A button that enables the boost airflow for the kitchen to be selected in hour steps By pass green LED On having avoided the heat exchanger the 100 by pass system of the energiSava...

Страница 17: ...Flow regulators mounted in the right direction if installed Air outlet using insulated duct and connected to the outside Using a roof cowl or outlet without an insect screen Insulated flexible ducts t...

Страница 18: ...REF 99999999 EnviroVent Ltd Envirovent House Hornbeam Business Park Harrogate Hg2 8PA 01423 810 810 info envirovent com www envirovent comm...

Отзывы: