SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

0845 27 27 810

ECO

2

 Air Twin & ECO

2

 Loftight Twin

INSTALLATION DIAGRAMS

STANDARD INSTALLATION

Installation diagram for the ECO

2

 Air Twin & ECO

2

 Loftight Twin

UNIT DIMENSIONS

Dimensions of the ECO

2

 Air Twin

Unswitched fuse spur fitted 

with 3 Amp fuse

230V A.C.

3 core mains lead

For fixing instructions, please 

refer to the fixing instructions 

(figure 1) on page 5

650mm x 50mm x 25mm batten

Ceiling joists

Contents for unit

1 x Cardboard template

2 x Diffuser

1 x Fixing kit

1 x Unswitched fuse spur

 

ø100mm Flexi duct

1 x Heater enable switch

 

or wireless control

1 x Filter

Supply Voltage

•  230V

•  50Hz

•  525W max

Heater enable/disable switch 

(Non Wireless-Heater version 

only)

Fresh air delivered 

into dwelling

Fresh air drawn 

from outside

405mm

 ø

150mm

 ø100 mm

Содержание ECO2 Air Twin

Страница 1: ......

Страница 2: ......

Страница 3: ...erly i e for the life of the building If the unit is mishandled you might break it This invalidates the warranty And remember if you have any problems please call our dedicated Technical Team We are a...

Страница 4: ...ECOMMENDATIONS All wiring must comply with Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for your country The final installation should be examined a...

Страница 5: ...fuse 230V A C 3 core mains lead For fixing instructions please refer to the fixing instructions figure 1 on page 5 650mm x 50mm x 25mm batten Ceiling joists Contents for unit 1 x Cardboard template 2...

Страница 6: ...the diagram below ECO2 Air Twin only Fig 1 Fixing Instructions FIRST STAGE Position a dustsheet beneath the site you have chosen for cutting the hole for the diffuser Protect your lungs with a mask E...

Страница 7: ...mm x 350mm min ridged duct See Fig 4 Filter Orientation The cone filter should always point towards ECO2 Air Twin and ECO2 Loftight Twin Fixing and sealing The filter should be fully sealed into the d...

Страница 8: ...ntenance For maximum efficiency of the unit it is recommended that the filter is cleaned every 24 to 36 months by a competent person Use a vacuum cleaner a soft brush or warm water air dry fully befor...

Страница 9: ...lled by a competent person and should be connected to an electrical supply in accordance with the current electrical regulations A disconnection device should be used in the fixed wiring Connect the h...

Страница 10: ...on constant for a few seconds Next press moves the unit to the next speed and so on When the speed is chosen the LED remains on for a few seconds If the two LEDs situated just above the button flash...

Страница 11: ......

Страница 12: ...n co uk E OE MKT ENV248 V3 28 03 14 Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice AFTER INSTALL...

Отзывы: