SHOULD YOU ENCOUNTER ANY PROBLEMS INSTALLING THIS UNIT CALL

0845 27 27 810

ECO

2

 Air Twin & ECO

2

 Loftight Twin

NINTH STAGE cont. - Wireless units only

For heater enable/disable

To change speed setting

On commission the unit 

will default to the trickle 

flow rate with heater 

enable on

Press button for five 

seconds turns heater 

enable off. LED will 

flash red for a few 

seconds

Press button for five 

seconds turns heater 

enable on. LED will 

show constant red for a 

few seconds

Press button once, to 

indicate current fan 

speed and heater status. 

LEDs stay on constant 

for a few seconds

Next press moves the unit to the 

next speed and so on. When the 

speed is chosen the LED remains 

on for a few seconds

If the two LEDs situated just above 

the button flash alternately red and 

green (when it is pressed) the control 

will need to be reprogrammed.  

Call your maintenance company or 

EnviroVent for advice.

Heater enable ON

Auto LED stays on constant for a few 

seconds.

Heater enable OFF

Auto LED flashes for a few seconds.

Boost

(Green)

Remote Control out of range (Red)

Heater enable

(Red)

Remote Control

in range

(Green)

When the battery needs replacing, unscrew the front 

cover. The battery is located on the back of the cover.  

Battery type - 3V Lithium, CR2032

(Green)

LED Colours

Constant Red

Flashing Red

Constant Green

Содержание ECO2 Air Twin

Страница 1: ......

Страница 2: ......

Страница 3: ...erly i e for the life of the building If the unit is mishandled you might break it This invalidates the warranty And remember if you have any problems please call our dedicated Technical Team We are a...

Страница 4: ...ECOMMENDATIONS All wiring must comply with Building Regulations and the current I E E Wiring Regulations BS7671 or the equivalent standards for your country The final installation should be examined a...

Страница 5: ...fuse 230V A C 3 core mains lead For fixing instructions please refer to the fixing instructions figure 1 on page 5 650mm x 50mm x 25mm batten Ceiling joists Contents for unit 1 x Cardboard template 2...

Страница 6: ...the diagram below ECO2 Air Twin only Fig 1 Fixing Instructions FIRST STAGE Position a dustsheet beneath the site you have chosen for cutting the hole for the diffuser Protect your lungs with a mask E...

Страница 7: ...mm x 350mm min ridged duct See Fig 4 Filter Orientation The cone filter should always point towards ECO2 Air Twin and ECO2 Loftight Twin Fixing and sealing The filter should be fully sealed into the d...

Страница 8: ...ntenance For maximum efficiency of the unit it is recommended that the filter is cleaned every 24 to 36 months by a competent person Use a vacuum cleaner a soft brush or warm water air dry fully befor...

Страница 9: ...lled by a competent person and should be connected to an electrical supply in accordance with the current electrical regulations A disconnection device should be used in the fixed wiring Connect the h...

Страница 10: ...on constant for a few seconds Next press moves the unit to the next speed and so on When the speed is chosen the LED remains on for a few seconds If the two LEDs situated just above the button flash...

Страница 11: ......

Страница 12: ...n co uk E OE MKT ENV248 V3 28 03 14 Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice AFTER INSTALL...

Отзывы: