Doc. No. MO-RKN-3009
Version 1.9: Sep. 07, 2010
20 (32)
CONTROL UNIT OPERATION
Checking Operation Mode
1) Press the "Menu/Enter" button to enter the main menu; the display shows "TEMP MENU".
2) Use the "Up" or "Down" button to step to "SYSTEM MENU" and press the "Menu/Enter"
button to confirm; the display shows "ALARM VIEW".
3) Use the "Up" or "Down" button to step to "OPER. MODE" and press the "Menu/Enter" button
to confirm.
4) Check current operation mode (refer to section "Operation modes, alerts and alarms").
5) Press "Back" button twice to return to default mode.
Battery Level Check
The battery level is shown in the default mode. The battery percentage figure is continously updated
according to battery status.
100% battery capacity is maximum and is achieved when charging starts from low battery
voltage.
95% battery capacity is considered fully charged if the blue light is fixed (not flashing). This
corresponds to at least 30 hours of running time within the specification.
30% battery capacity corresponds to at least 12 hours of running time within the specification.
Seal Control Unit and Info Button
Use the rectangular opening in the latch to seal the control unit. Use a seal with a x-section of at
least 2 mm (0.08 in).
After the control unit has been sealed it is still possible to view information on the display using
the info button.
1) Press the info button (Figure 15) to scroll between default mode, alarm status and alert status.
The backlight is illuminated when the button is pressed.
Note!
It is only possible to toggle through the menu with this button but no changes to the set temp
or other can be made.
Info button
Figure 15
Opening for seal