TABLE 4 – Unit Supply Opening Sizes
UNIT SUPPLY OPENING SIZES
Model
Horizontal Openings
Top
Opening
Single Horizontal
Double Horizontal
Triple Horizontal
No Top Opening w/ Top Opening No Top Opening w/ Top Opening
No Top Opening
09
14W x 12H
14W x 6H
14W x 8H
Not Available
Not Available
12x8
12
14W x 14H
14W x 6H
14W x 10H
Not Available
Not Available
12x8
15
16W x 14H
14W x 6H
14W x 10H
Not Available
14W x 8H
14x12
18
Not Available
14W x 6H
14W x 12H
14W x 6H
14W x 10H
14x12
24
Not Available
14W x 10H
16W x 14H
14W x 6H
14W x 10H
14x12
30
Not Available
14W x 6H
20W x 14H
14W x 6H
16W x 12H
18x16
36
Not Available
14W x 10H
Not Available
14W x 6H
16W x 14H
18x16
1. Unit supplied supply grilles wil be supplied as double-deflection type.
2.Grilles for unequal airflow applications (i.e. unit-mounted plus ducted supply) shall be provided with integral opposed-blade dampers.
3. All grilles will be supplied in standard “Appliance White” painted finish.
4. Grilles are shipped loose, for field installation upon completion of cabinet/ductwork/drywall installation.
5. Top opening size does not change. When combined with any other discharge arrangement, shallbe be included in determining horizontal
opening grille size.
6. Openings marked ‘Not Available’ result in face velocities outside the recommended 300-500 FPM range.
7. Hi-Static Blower option is not recommended or single horizontal discharge openings with unit mounted supply grille.
UNIT SUPPLY FACE VELOCITY (FPM)
Model
Horizontal Openings
Top
Opening
Single Horizontal
Double Horizontal
Triple Horizontal
No Top Opening w/ Top Opening No Top Opening w/ Top Opening
No Top Opening
09
291
272
219
Not Available
Not Available
510
12
316
344
221
Not Available
Not Available
645
15
354
314
283
Not Available
236
471
18
Not Available
391
294
294
235
587
24
Not Available
397
273
364
291
729
30
Not Available
416
276
339
269
538
36
Not Available
410
Not Available
385
261
610
1. Tabulated Face velocities do not account for supply grille free area factor. Face velocities at supply grille will be higher depending on grille type.
2.Face velocities are based on the nominal rated CFM and in feet per minute (FPM).
3. Face velocities are calculated by taking the averate across all openings. Tabulated top opening face velocity is only for units with single Top
Opening and no horizontal openings.
Содержание VB09-36
Страница 6: ...FORM ET145 18 IOM1 115 ENVIRO TEC 6 FIGURE 1 Cabinet Chassis Model Nomenclature ...
Страница 7: ...FORM ET145 18 IOM1 115 ENVIRO TEC 7 ...
Страница 19: ...FORM ET145 18 IOM1 115 ENVIRO TEC 19 FIGURE 9A Optional Return Air Panel with ADA Mounted Thermostat ...
Страница 21: ...FORM ET145 18 IOM1 115 ENVIRO TEC 21 FIGURE 11 Unit Mounted Supply Grille Installation Dimensions ...
Страница 34: ...FORM ET145 18 IOM1 115 ENVIRO TEC 34 APPENDIX PSC MOTOR WIRING DIAGRAM ...
Страница 35: ...FORM ET145 18 IOM1 115 ENVIRO TEC 35 ECM WIRING DIAGRAM ...
Страница 36: ...FORM ET145 18 IOM1 115 ENVIRO TEC 36 CONTINUOUS FAN WITH ECM WIRING DIAGRAM ...
Страница 37: ...FORM ET145 18 IOM1 115 ENVIRO TEC 37 MOTORIZED DAMPER ECM WIRING DIAGRAM ...
Страница 39: ...FORM ET145 18 IOM1 115 ENVIRO TEC 39 NOTES ...