14
Maintenance And Service
8. Reinstall the burner, coal set, and glass door.
Also refer to
s
econDary
I
nstallatIon
- c
oal
s
et
I
nstallatIon
in your Owner’s Manual.
When re-
installing the burner, ensure that the burner to
pilot shield relationship is similar to what is shown
in Figure 15.
9.
Reconnect the main gas line if it was disconnected
and open the shut-off valve at the gas line to the
unit.
10. Use a small brush to apply a warm soapy water
solution to all gas connections (use a half dish
soap and half warm water). If a gas leak is
present, bubbling will occur. Gas leaks can be
repaired by using an approved pipe thread sealant
or approved Teflon tape. NEVER USE AN OPEN
FLAME WHEN TESTING FOR LEAKS.
Figure 14: O-ring on valve screw.
11.
Reconnect the electrical power to the unit.
12. Relight the pilot and confirm the flame properly covers both the thermocouple and thermopile (see
Figure 4, page 8)
.
Should the pilot require adjustment, turn the adjustment screw (figure 42, page
35) clockwise to decrease or counterclockwise to increase until the correct flame is achieved.
13.
Relight the main burner in both the “HI” and “LO” positions to verify proper burner ignition, operation
and proper flame appearance. Confirm the inlet and manifold pressures are within the acceptable
ranges as directed in section
I
ntIal
I
ntallatIon
- g
as
l
Ine
c
onnectIon
anD
t
estIng
.
If the Q1 has
been installed at an altitude higher than 2000ft (610m) it is required to de-rate the unit accordingly:
In the USA:
The appliance may be installed at higher altitudes. Please refer to your American Gas
Association guidelines which state: the sea level rated input of Gas Designed Appliances installed at
elevations above 2000 (610 m) feet is to be reduced 4% for each 1000 feet (305 m) above sea level.
Refer also to local authorities or codes which have jurisdiction in your area regarding the de-rate
guidelines.
In Canada
: When the appliance is installed at elevations above 4500 feet (1372 m), the certified high
altitude rating shall be reduced at the rate of 4% for each additional 1000 feet (305 m).
14. MAKE SURE that the conversion label is installed on or close to the rating label to signify that the
unit has been converted to a different fuel type.
Figure 15. Pilot assembly
beside the burner.
g) Re-attach the black protection
cap that was removed in step
a (Figure 11).