31
Initial Installation
QUALIFIED INSTALLERS ONLY
a
ir
r
estrictor
s
ettings
:
When installing the Q1C with 8ft (2.44M) or more of vertical venting, either co-axial or co-linear, it may be
necessary to restrict the fresh air supply in the firebox to control the combustion and flame appearance.
Using the pair of air restrictors supplied with the unit, install them on each side of the firebox and adjust
to the correct setting as outlined in the figure and table below. To install the air restrictors first you
must remove the log set, air diffuser, and creamic brick panels (see
s
econDary
I
nstallatIon
- o
ptIonal
p
orcelaIn
p
anels
I
nstallatIon
anD
r
eMoVal
)
then remove the set screws as shown on each side of the
firebox. Next, install the restrictors at the correct setting and tighten the set screws to hold them in place.
Air Restrictor Settings
Length of Vertical Vent
Propane
Natural Gas
Less than 8ft (2.44m) co-linear or co-axial
No Restriction Required
No Restriction Required
8ft (2.44m) - 20ft (6.1m) co-linear or co-axial
No Restriction Required
No Restricition Required
Through Roof Termination, more than 20ft
(6.1m) to 40ft (12.19m) co-linear
Setting #2
Setting #3
Through Roof Termination, more than 20ft
(6.1m) to 40ft (12.19m) co-axial
Setting #1
Setting #1
A
#3
#2
#1
Set Screw
Figure 41: Installation of Air Restrictors
Table 9: Air Restrictor Settings