![Enviro Meridian Cast Iron Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/enviro/meridian-cast-iron/meridian-cast-iron_owners-manual_2415781012.webp)
EXHAUST
Base of unit to center of flue
15 ⅝”
(400 mm)
Side of unit to center of flue
9”
(229 mm)
Center of unit to center of flue
5 ¾”
(146 mm)
FRESH AIR INTAKE.
Base of unit to center of intake 9
7
/
8
”
(251 mm)
Side of unit to center of intake 13
3
/
4
”
(349 mm)
Center of unit to center of flue
1”
(25 mm)
13 3/4"
(349mm)
9"
(229mm)
1"
(25mm)
9 7/8"
(251mm)
5 3/4"
(146mm)
15 5/8"
(400mm)
o
utSiDe
f
ReSh
-a
iR
c
onnection
:
Installation
e
xhauSt
a
nD
f
ReSh
a
iR
i
ntake
L
ocationS
:
2" ID
(51 mm)
Optional
Elbow
Outside
Wall
Figure 9: Outside Air Connection.
Figure 8: Meridian Cast Iron Inlet and Outlet Location.
12
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING MANUFACTURER
Outside fresh air is mandatory when installing this unit in
airtight homes and mobile homes.
A Fresh-air intake is strongly recommended for all
installations. Failure to install intake air may result in improper
combustion as well as the unit smoking during power failures.
When connecting to an outside fresh air source, do not use plastic
or combustible pipe. A 2” minimum (51 mm) ID (inside diameter)
steel, aluminum or copper pipe should be used. It is recommended,
when you are installing a fresh air system, to keep the number of
bends in the pipe to a minimum.
Содержание Meridian Cast Iron
Страница 35: ...MERIDIAN CAST IRON Components May 2015 4 11 1 10 6 2 9 7 5 3 8 Parts Diagram Components 35...
Страница 38: ...Notes 38...
Страница 39: ...39...