44
e
xhaust
R
estRictoR
s
ettinG
:
WARNING: Improperly set restrictor setting can cause overheating issues which can lead to
building fire.
It may be necessary to adjust the exhaust restrictor in order to control combustion quality and flame
appearance. There are six different restrictor settings.
Determine what restrictor setting you require using the vent graphs in “
I
nItIal
I
nstallatIon
- a
llowable
c
o
-
axIal
V
ent
c
onfIguratIons
. The restrictor is set to 1 when the flat edge of the dial is vertical (see Figure
63). Rotate the dial counter-clockwise to increase the restriction level successively until the appropriate
setting is achieved. When the flat edge is horizontal the restrictor level is at its maximum (see Figure 62).
The proper setting is crucial for an efficient burn and best possible flame appearance.
It may be necessary to deviate from the recommended setting as different altitudes and climates can
vary the operation of the fireplace. With LP fueled fireplaces, it is always a good idea to offer slightly less
restriction for higher altitudes to reduce the risk of sooting over an extended period.
Initial Installation
QUALIFIED INSTALLERS ONLY
Figure 63. Restrictor Setting 1
Figure 62. Restrictor Setting 6
9.00
9.00
A
B
DETAIL
A
SCALE
2 : 5
DETAIL
B
SCALE
4 : 5
9.00
9.00
A
B
DETAIL
A
SCALE
2 : 5
DETAIL
B
SCALE
4 : 5
Step 1.
Remove surround panel to gain access to restrictor control.
Step 2.
Use a 7/16 socket with long extension to adjust the restrictor dial to desired setting.
Step 3.
Allow unit to warn up sufficently and make adjustment as needed.
Step 4.
Allow unit to cool down and reinstall surround panel.