10
o
peRatinG
p
RoceDuRe
:
Initializing The System
Install the four (4) supplied AA batteries into the IFC battery holder. The remote transmitter should come from
the manufacturer with the batteries already installed. Press the reset button on the IFC (see Figure 5) and
listen for three (3) beeps. Press the ON key on the remote transmitter and listen for another beep sequence.
Once the command has been accepted then the system is initialized and ready for use.
Note: Other remote transmitters may interfere with the system if you have another within the
vicinity.
Figure 6: Temperature Scale Display
Operating Instructions
Figure 7: CPI Pilot Mode.
Note: If the pilot takes too long to ignite there may be air in the gas line. The system will enter a 5
minute lock-out and cancel the start-up procedure if too many spark attempts have been made. If
pilot cannot light after 3 lock-out cycles then contact your gas fitter.
Temperature Indication Display
Press the Thermostat key and the Mode key
simultaneously while the system is OFF. The remote
transmitter will indicate which temperature scale is
being displayed (°C or °F). Repeat this sequence to
change the scale (see Figure 6).
Turn off the Appliance
Press the ON/OFF key on the transmitter to turn the fireplace off. The IFC will confirm your command with a
single beep. The pilot light (IPI) and the main burner will turn off. The pilot will remain lit if the fireplace is in CPI
mode. Room temperature information will still be displayed on the remote when the unit is off.
Note: It is recommended to use CPI mode
when the temperature outside is below 50
°F
(10°C) to keep the vent sufficiently heated to
assist with warm-up procedure. Using CPI will
also eliminate excessive condensation on the
glass during start-up.
Note: This appliance is equipped with an on-
demand pilot that, if left dormant, will shut
down after 7 consecutive days.
Continuous Pilot Mode
Press the Mode key with the fireplace turned off. Use the UP/DOWN key to cycle between intermittent pilot
ignition (IPI) and continuous pilot ignition (CPI). Press the mode key to make your selection and the IFC will
beep to confirm your command.
Turn on the Appliance
Press the ON/OFF key on the remote transmitter; the display will illuminate and show all active icons. A single
beep from the IFC will confirm the command from the remote and the start up sequence will begin. The spark
electrode will ignite the pilot flame which will engulf the flame sensor hook. After the sensor reaches sufficient
temperature, the main burner valve will open and the flame will ignite moments after.