QUALIFIED INSTALLERS ONLY
Table 6: Approved Vent Manufacturers
Manufacturer
Trade Name
Nominal Sizes
ICC
EXCELDirect
4” - 6
5/
8
”
M&G Dura-Vent
Direct Vent Pro
4” - 6
5/
8
”
Selkirk
DIRECT-TEMP
4” - 6
5/
8
”
Selkirk
AMP DV
4” - 6
5/
8
”
This fireplace has been tested and certified for use with M&G DuraVent DirectVent Pro, ICC EXCEL Direct,
Selkirk DIRECT-TEMP, and Selkirk AMP DV venting systems. Refer to the table below for part numbers
of commonly used parts for both venting systems. For more venting parts please visit the respective
manufacturers’ website.
WARNING: Do not mix parts from different vent manufacturers’ systems.
EXCEPTION TO WARNING:
This product has been evaluated by Intertek for using a DirectVent Pro
starting collar in conjunction with EXCELDirect venting systems. Use of this system with the DirectVent
Pro starting collar is deemed acceptable and does not affect the Intertek listing of the appliance.
a
PPRoVeD
V
entinG
P
aRts
:
Table 6A: Vent Part Numbers
(must state if galvanized or black wanted)
Direct Vent Pro
EXCELDirect
DIRECT-TEMP
AMP DV
Description
46DVA-06
4DL6
4DT-06
6” pipe length
4D7
7" pipe length
46DVA-09
4DL9
4DT-09
9” pipe length
46DVA-12
4DL1
4DT-12
4D12
12” pipe length
46DVA-16
4DT-16
18” pipe length
46DVA-24
4DL2
4DT-24
4D2
24” pipe length
46DVA-36
4DL3
4DT-36
4D3
36” pipe length
46DVA-48
4DL4
4DT-48
4D4
48” pipe length
46DVA-60
60” pipe length
46DVA-E30
30° elbow, black
46DVA-E45
4DE45
4DT-EL45
4D45L
45° elbow, black
46DVA-E90
4DE90
4DT-EL90
4D90L
90° elbow, black
46DVA-VSS, DVA-BVS
VSS
4DT-VS, VSK
4DHVS, DVSK
Vinyl siding standoff/sheild
46DVA-WT, 46DVA-WTU
4WT
4DT-WT
4DWT
Wall thimble
46DVA-SC
SQSC, SC
4DT-SC
4DSC
Storm collar
46DVA-WFS
4DT-FS
Wall Fire stop
46DVA-FS
4CS
4DT-FS
4DFSP
Ceiling Fire stop
46DVA-IS
4AS
4DT-AIS
4DAIS12, AIS36
Attic Insulation Shield
46DVA-WS
4WS
4DT-WS/B
4DWS
Wall strap/support/band
46DVA-VCH
4SVT
4DT-VT
4DVC
High wind vertical termination
46DVA-17TA
11” to 17” pipe, adjustable
46DVA-24TA
17” to 24” pipe, adjustable
4DLA30
16.5” to 29” pipe , adjustable
4DLS1
1 7/8” to 9” slip length pipe
4DLS2
1 7/8” to 21” slip length pipe
4D7A
3" to 5" pipe, adjustable
4DT-AJ12
4D12A
4" to 10" pipe, adjustable
4D16A
3" to 14" pipe, adjustable
4D26A
3" to 24" pipe, adjustable
4DT-TL14
14" to 22" pipe, telescopic
4DT-TL36
38" to 70" pipe, telescopic
46DVA-F6
6EFA
4DT-AF6
4DF
Flashing, 0/12 to 6/12 roof pitch
46DVA-F12
6EFB
4DT-AF12
4DF12
Flashing, 7/12 to 12/12 roof pitch
46DVA-FF
6EF
Flat Roof Flashings
46DVA-CFK
4MF
Masonary Flashing
4DT-MCK
4DRCKM
Masonry Conversion Kit
Содержание G39L