Safety Precautions

FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, 

PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:

•  All  ENVIRO  gas-fired  appliances  must  be  installed  in 

accordance with their instructions. Carefully read all the 

instructions  in  this  manual  first.  Consult  the  building 

authority having jurisdiction to determine the need for a 

permit prior to commencing the installation.

•  

NOTE: Failure to follow these instructions could cause 

a malfunction of the fireplace, which could result in death, 

serious bodily injury, and/or property damage.

• Failure to follow these instructions may also void your 

fire insurance and/or warranty.

GENERAL

•  Installation  and  repair  should  be  done  by  a  qualified 

service person. The appliance should be inspected before 

the first use and, at least, annually by a qualified service 

person. More frequent cleaning may be required due to 

excessive lint from carpeting, bedding material, etc.  It 

is imperative the control compartments, burners and 

circulating air passageways of the appliance be kept 

clean.

•  Due  to  high  temperatures,  the  appliance  should  be 

located out of high traffic areas and away from furniture 

and draperies.
Children and adults should be alerted to the 

hazards of high surface temperatures and should 

stay away to avoid burn or clothing ignition.

• Young children should be carefully supervised when in 

the same room as the appliance.  Toddlers, young children 

and others may be susceptible to accidental contact 

burns.  A physical barrier is required if there is a risk for 

individuals in the house.  To restrict access to a fireplace 

or stove install an adjustable safety gate to keep toddlers, 

young children and other at risk individuals out of the 

room and away from hot surfaces. Any safety screen, 

guard, or barrier removed for servicing an appliance must 

be replaced prior to operating the appliance.

•  Clothing  or  other  flammable  materials  should  not  be 

placed on or near the appliance.

• A barrier designed to reduce the risk of burns from the 

hot viewing glass is provided with this appliance and shall 

be installed for the protection of children and other at-risk 

individuals. If the barrier becomes damaged, the barrier 

shall be replaced with the manufacturer’s barrier for this 

appliance.
FOR YOUR SAFETY

• Installation and service must be performed by a qualified 

installer, service agency or gas supplier.

•  This  installation  must  conform  to  local  codes  or,  in  the 

absence  of  local  codes,  with  the  National  Fuel  Gas  Code, 

ANSI  Z223.1/NFPA  54,  or  the  Natural  Gas  and  Propane 

Installation Code, CSA B149.1.
• To prevent injury, do not allow anyone who is unfamiliar 

with the stove to operate it.

 

To prevent injury, if the pilot or pilot and burners 

have gone out on their own, open the glass door and 

wait  5  minutes  to  air  out  before  attempting  to  re-

light the stove.

•  Always  keep  the  area  around  these  appliances  clear  of 

combustible material, gasoline and other flammable liquids 

and vapours.

• These appliances should not be used as a drying rack for 

clothing or for hanging Christmas stockings/decorations.
• Due to the paint curing on the stove, a faint odor and slight

 

smoking will likely be noticed when the stove is first used.  

Open a window until the smoking stops.
Always connect this gas stove to a vent system and vent to 

the outside of the building envelope. Never vent to another 

room  or  inside  the  building.  Make  sure  the  specified  vent 

pipe is used, properly sized and of adequate height to 

provide sufficient draft.  Inspect the venting system annually 

for blockage and signs of deterioration.
WARNING:  Failure to position the parts in accordance 

with the diagrams in this booklet, or failure to use only 

parts specifically approved with this appliance, may result in 

property damage or personal injury.
WARNING: 

Do not operate with the glass front removed, 

cracked or broken.  Replacement of the glass should be done 

by a licensed or qualified service person.
• Never use solid fuels such as wood, paper, cardboard, coal, 

or any flammable liquids, etc., in this appliance.
• Do not use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 

appliance and to replace any part of the control  system or 

any gas control which has been under water.

• Do not abuse the glass by striking it or slamming the door 

shut.

• If the G39 unit is pulled out of its installation, and the vent-

air intake system is disconnected for any reason, ensure that 

the vent-air intake pipes are reconnected and re-sealed in 

accordance to the instructions noted in 

I

nItIal

 I

nstallatIon

 

- D

Irect

 V

ent

HOT GLASS 

WILL 

CAUSE BURNS

DO NOT TOUCH 

GLASS 

UNTIL COOLED. 

NEVER

 ALLOW CHILDREN

TO TOUCH GLASS. 



A barrier designed to reduce the risk of burns from the

hot viewing glass is provided with this appliance and shall 

individuals.

Содержание G39L

Страница 1: ...r loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html C 4001609 W A R R A N T Y R E G I S T R A...

Страница 2: ...immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service m...

Страница 3: ...st be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA...

Страница 4: ...16 Unit Install Preparation 16 Placement and Framing 19 Cool Surface Framing 20 Cool Surface Activation 23 Floor Protection 24 Mantel Requirements 24 Flat Wall Installation 25 Recess Installation 26...

Страница 5: ...7 CSA 2 33 2017 VENTED GAS FIREPLACE HEATERS CAN CGA 2 17 2017 GAS FIRED APPLIANCES FOR HIGH ALTITUDES This ENVIRO G39 Fireplace Has been certified for use with either natural gas or propane see ratin...

Страница 6: ...important information for your fireplace is on this label as well as the model specific serial number which you will need for warranty information The sheet is located inside the cabinet under the gas...

Страница 7: ...to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in...

Страница 8: ...e first time it should be turned onto high with the fan OFF for the first two to four hours This will cure the paint logs gasket material and other products used in the manufacturing process It is adv...

Страница 9: ...losing Blower speed For Your Safety Read Safety Precautions And Lighting Instructions Before Operating Air Shutter Venturi The air shutter plays a very important role in flame appearence and combustio...

Страница 10: ...he amount of use the glass should require cleaning no more than two or three times a season WARNING Do not clean the glass when it is hot Cleaning The Firebox Carefully remove the logs they are fragil...

Страница 11: ...uick wipe with denatured alcohol on a soft cloth BEFORE lighting the fireplace Never clean the face when it is hot Do not use other cleaners as they may leave a residue which can become permanently et...

Страница 12: ...WARNING Do not touch or attempt to remove the glass door if the fireplace is not completely cold WARNING Never operate the fireplace with the glass door removed Figure 8 Door Cover Removal Door Cover...

Страница 13: ...fore installing Warning This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the authori...

Страница 14: ...ure not to overtighten pilot if head does not reach the proper orientation in the snug position then contact your Enviro dealer Slide 1 Disconnectthegassupplycompletelyaswellasanyelectricalpowersource...

Страница 15: ...FIX THIS LINE IT MUST BE REPLACED IF DAMAGED The pilot should properly cover both the thermocouple and thermopile If adjustment is necessary turn the adjustment screw in the valve see Figure 50 clockw...

Страница 16: ...manual 4 5 6 3 2 1 Diagram 1 Additional Parts Unit Install Preparation Review the diagram below to familiarize yourself with the parts included with the unit Please review the following instructions c...

Страница 17: ...Cabinet Holster Removal Step 2 There are four 4 nailing flanges to secure the unit to the framing they are assembled flat from the manufacturer Remove the upper T 20 screw and rotate each nailing fla...

Страница 18: ...ed non combustible facing board with eight 8 supplied 8 32 x 75 fasteners and a 1 4 inch socket These screws can be found in the manual bag remove them and install the board Line up the holes and dril...

Страница 19: ...can be raised at floor level or installed in a corner There are minimum framing measurements for each situation The basic rough opening should have the following dimensions see Figure 23 The fireplace...

Страница 20: ...it is crucial that the chase is vented in accordance to this manual There are a few different options available to frame your CSS Figure 24 Framing Option 1 Initial Installation QUALIFIED INSTALLERS...

Страница 21: ...in conjunction with this option 2 51mm Minimum 15 381mm Minimum 6 152mm Minimum Wall Mounted Object Optional Acessory Valance A valance may be desired to accentuate the CSS outlet Consider framing opt...

Страница 22: ...bustible materials inside the chase see Figure 27 Note If you wish to construct a similar cutout part way up a tall wall then it is essential to build a false ceiling inside the chase at the desired h...

Страница 23: ...t is not permitted to vent the chase into an adjoining room The CSS bleeds heat off the fireplace into the chase as opposed to climbing up the front face This dramatically lowers the front wall temper...

Страница 24: ...7 8 9 10 11 12 13 14 M A N T E L H E I G H T M A N T E L D E P T H Minimum Mantle Clearances 8 MANTEL 4 MANTEL 52 51 50 49 48 47 46 44 45 12 MANTEL Diagram 2 Mantel Graph Floor Protection Figure 30 A...

Страница 25: ...ALLERS ONLY Figure 31 Flat Wall Installation Minimum Height to Ceiling Flat Wall Installation These are the minimum allowable dimensions required to safely operate the fireplace Plan your entire insta...

Страница 26: ...d Initial Installation QUALIFIED INSTALLERS ONLY Recess Installation These are the minimum allowable dimensions required to safely operate the fireplace Plan your entire installation before proceeding...

Страница 27: ...are the minimum allowable framing dimensions required to safely operate the fireplace in a corner install Plan your entire installation before proceeding Figure 33 Corner Installation 1 25mm 15 382mm...

Страница 28: ...ation from the minimum vertical length can create difficulty in burner start up and sooting Allow several minutes for the flame to stabilize after ignition under extreme vent configurations It is reco...

Страница 29: ...Form and Duravent flexible direct venting systems Not all rigid venting configurations are allowable when using flex venting Only horizonally terminated applications will work with a vertical rise bet...

Страница 30: ...composed of combustible material Mantel It is not necessary to install a mantel but if one is desired the guidelines as shown in Initial Installation Mantel Requirements Floor The unit must be raised...

Страница 31: ...Shiplap Extended Tiling Flange 1 2 13mm Drywall 7 8 22mm Mimimum 13 3 8 341mm Supplied Non Combustible Board Extended Tiling Flange 1 2 13mm Supplied Non Combustible Board Standard Cool Surface Syste...

Страница 32: ...s maximum allowable temperature Mantel Only Installaton Always maintain minimum clearances see Figure 37 The total depth of the TV including the wall mount will determine the minimum allowable mantel...

Страница 33: ...line extended above me ter regulator assembly I 3 ft 91 cm 3 ft 91 cm Radial clearance around service regulator vent outlet Table 4 Vent Termination Clearances Vent Termination Restrictions WARNING Fo...

Страница 34: ...bustibles must be maintained around any vertical vent pipe Around a horizontal vent pipe the clearance to combustibles should be 3 76 mm above and 1 25 mm on the sides and bottom When combustible mate...

Страница 35: ...ipe length 46DVA 12 4DL1 4DT 12 4D12 12 pipe length 46DVA 16 4DT 16 18 pipe length 46DVA 24 4DL2 4DT 24 4D2 24 pipe length 46DVA 36 4DL3 4DT 36 4D3 36 pipe length 46DVA 48 4DL4 4DT 48 4D4 48 pipe leng...

Страница 36: ...ust be subtracted from the allowable horizontal run for each 45 elbow 1 feet 45 7cm must be subtracted Restrictor Setting Find the point on the graph where your vent configuration will terminate Remem...

Страница 37: ...the graph See the following section in this manual for restrictor details Your climate and altitude may alter what restrictor is required for your particular application Figure 42 LP Vent Graph 3 0 91...

Страница 38: ...horizontal the restrictor level is at its maximum see Figure 43 The proper setting is crucial for an efficient burn and best possible flame appearance It may be necessary to deviate from the recommen...

Страница 39: ...ortion of the standoff which provides an air space between the wall and the vent termination The air gap prevents excessive heat from possibly melting the vinyl siding 6 Horizontal pipes must be suppo...

Страница 40: ...Do not pack air spaces with insulation Step 2 Set the fireplace in the desired location Drop a plumb bob down from the ceiling to the fireplace flue exit and mark the location where the vent will pen...

Страница 41: ...2 13 Over 18 12 to 20 12 7 5 2 29 Over 20 12 to 21 12 8 2 44 Figure 47 Height of Vertical Termination Reference Table 7 45 elbows x2 Wall strap Plumber s tape connected to wal strap Figure 49 Use of W...

Страница 42: ...valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water solution after completing the r...

Страница 43: ...e the fireplace This model has a millivolt gas control system which uses the pilot flame to generate enough electricity to opeate the main burner External electricity is only required to operate the c...

Страница 44: ...ACK WHITE Initial Installation QUALIFIED INSTALLERS ONLY Figure 52 Convection Fan Wiring Diagram Convection Fan Wiring Use this wiring diagram to diagnose any problems relating to the convection fan c...

Страница 45: ...can irritate your skin Take care not to damage the liners as they are very fragile and can chip easily If handeling porcelain liners it is still a good idea to wear gloves as the oils from your finger...

Страница 46: ...age the logs as they are very fragile and can chip easily If any logs arrive damaged please contact your ENVIRO dealer for replacement LOG 1 LOG 8 LOG 9 LOG 6 LOG 5 LOG 7 LOG 4 LOG 2 LOG 3 Step 2 Plac...

Страница 47: ...s Line up the Log 3 bottom sockets with the points on the ember bed Step 4 Place Log 4 to the right on the top of Log 1 and Log 2 Step 6 Place Log 6 between the grate arms with the bottom socket resti...

Страница 48: ...Log 7 at an angle on top of Log 6 Step 8 Place Log 8 between the grate arms with the bottom socket resting on the edge of the ember bed Step 9 Place Log 9 between the grate arms with the bottom socket...

Страница 49: ...ilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas line pressure...

Страница 50: ...n Controller W FS Knob EC 039A 11 120 Degree F Fan Temperature Sensor EC 001 PVC Wire Clip 50 3614 12 Painted Black Liners 50 3536 Porcelain Liners 50 3498 Brown Brick Liners 50 3410 Herringbone Liner...

Страница 51: ...51 Parts Diagram 1 2 3 5 13 6 7 14 8 9 10 11 12 4...

Страница 52: ...52 Notes...

Страница 53: ...een mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from over...

Страница 54: ..._________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm y...

Отзывы: