9
Installation
O
PTIONAL
H
EARTH
P
AD
I
NSTALLATION
:
This unit can be installed on a combustible floor (e.g. linoleum, hardwood flooring) when the Optional
Hearth Pad is installed. If this unit is to be installed onto a carpeted surface, a solid pad must be used
underneath the Optional Hearth Pad for stability.
Carefully place the the pellet appliance on its back, on the pallet (allow the exhaust tube to fit thru an
opening in the pallet). Align the holes in the hearth pad and the unit and install the four (4) screws
provided. Stand the unit back up. Adjust the leveling legs to below the Hearth Pad, to support the weight
of the unit.
When moving the unit - be careful not to damage the floor or the Hearth Pad.
��������
���� ��
Figure 6: Installing Hearth Pad Pedestal onto EF5.
T
HERMOSTAT
I
NSTALLATION
:
1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the
desired area.
2. Install a 12 or 24 Volt Thermostat using an 18 x 2
gauge wire from the unit to the thermostat.
If the unit has been placed in the HI / LOW mode, the unit
will be taken to a low or idle setting when the thermostat
is not calling for heat. When the thermostat calls for heat,
the unit will go to the setting that is displayed on the
control board Heat Indicator. If the heating load is not
great enough when the stove is on low, the high limit
switch will turn the stove off and the switch will have to
be manually reset. To reset the high limit switch, remove
the right cabinet side. The switch is found behind the
control panel. Avoid setting off the high limit switch.
Figure 7: Thermostat wire placement.