Installation
T
HERMOSTAT
I
NSTALLATION
:
1. Install the wall thermostat in a location that is not to close too the unit but will effectively heat the
desired area.
Figure 23: Thermostat wire placement.
2. Install a 12 or 24 Volt Thermostat using an 18 x 2
gauge wire from the unit to the thermostat.
If the unit has been placed in the HI / LOW mode, the unit
will be taken to a low or idle setting when the thermostat
is not calling for heat. When the thermostat calls for
heat, the unit will go to the setting that is displayed on
the control board Heat Indicator. If the heating load is
not great enough when the stove is on low, the high limit
switch will turn the stove off and the switch will have to
be manually reset. To reset the high limit switch, remove
the right cabinet side. The switch is found behind the
control panel. Avoid setting off the high limit switch.
Figure 25: Slider / Damper
A Qualified Service Technician
or Installer must set the Slider
Damper
.
Note:
Some parts have been
removed in order to see the
components more clearly
Slider Damper
Plate
Exhaust
Channel
Exhaust
Blower Motor
Door Cut
Away
Figure 24: Slider / Damper Collars
S
LIDER
/D
AMPER
S
ETTING
:
THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION, IT IS USED TO REGULATE
THE AIRFLOW THROUGH THE PELLET STOVE.
The slider damper is located on the lower left side.
20