25
11
CONVECTION FAN CONTROLLER.
This controller is responsible for varying the speed of the convection blower.
12
200
°
F (93
°
C) MANUAL RESET TEMPERATURE SENSOR.
This sensor (located on the right side hopper) has a red button located in the center of the sensor. This sensor will
turn the auger OFF if the hopper reaches 200
°
F (93
°
C). Depress the button to reset if the sensor has been
activated.
13
120
°
F (49
°
C) N/O, TEMPERATURE SENSOR (SHUT-DOWN SENSOR).
This sensor (mounted on the exhaust blower housing) has two functions:
Should the fire go out, this sensor will shut the stove off when the exhaust temperature drops below 120
°
F (49
°
C).
When the auger is turned off via the dial-a-fire, the exhaust temperature will drop, when it goes below 120
°
F
(49
°
C) the sensor will turn the stove off.
14
120
°
F (49
°
C) N/C, TEMPERATURE SENSOR (IGNITER SHUT DOWN SENSOR).
This sensor (mounted on the exhaust channel) will turn the igniter off when the firebox temperature reaches
120
°
F (49
°
C).
15
EXHAUST/COMBUSTION BLOWER.
This variable speed fan (mounted on the left side of the stove) is responsible for drawing the outside fresh air into
the combustion chamber for burning. The hot air then continues to be drawn over the heat exchanger tubes and
into the exhaust channel. It is then pushed out through the exhaust system. A motor speed controller tied in with
the Dial-A-Fire controls the speed of the blower.
16
VACUUM SWITCH.
This safety device (mounted on the left side back pillar) detects vacuum in the exhaust system. If the exhaust
blower fails or the vent pipe becomes plugged, this switch will sense that there is no airflow and will stop the
auger from continuing to feed pellets.
17
THERMOSTAT INTERFACE.
This control module is responsible for switching between a factory setting (for auger timing and exhaust voltage)
and the control panel settings when the wall thermostat calls for heat.
Exhaust trim:
Used to increase or decrease voltage to exhaust blower.
Auger trim
:
Used to increase the fuel feed rate for poor or lesser quality fuels.
Thermostat hook up:
Install a 12 or 24, volt thermostat in this location.
AUGER
TRIM
EXHAUST
TRIM
THERMOSTAT