IMPORTANT SAFETY DATA
To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering to the
installation instructions. An ENVIROFIRE dealer will be happy to assist you in obtaining information
with regards to your local building codes and installation restrictions.
The stove’s exhaust system works with negative combustion chamber pressure and a slightly positive
chimney pressure, it is very important to ensure that the exhaust system be sealed and airtight.
This unit is designed to burn pelletized wood fuel only. Do not use any other type of fuel, this will void
any warranties stated in this manual.
THE USE OF CORDWOOD IS PROHIBITED BY LAW.
Do not burn with insufficient combustion air. A periodic check is recommended to ensure proper
combustion air is admitted to the combustion chamber. Setting the proper combustion air is achieved
by adjusting the slide damper located on the left side of the stove.
It is advisable to clean the exhaust vent bi-annually or every two tons of pellets.
The grounded electrical cord should be connected to a standard 115 volts, 60-hertz electrical outlet. Be
careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces
or sharp edges. This unit’s maximum power requirement is 520 watts (4.52 Amps) for the EF-IV Bi.
Minor soot or creosote may accumulate when the stove is operated under incorrect conditions such as
an extremely rich burn (black tipped, lazy orange flames).
When installing the stove in a mobile home, it must be electrically grounded to the steel chassis of the
home and bolted to the floor. Make sure that the structural integrity of the home is maintained.
Be sure to maintain the structural integrity of home when passing a vent through walls, ceilings, or
roofs.
The ash pan must be locked securely for proper and safe operation of the pellet stove.
If you have any questions with regards to your stove or the above-mentioned information, please feel
free to contact your local dealer for further clarification and comments.
Since Sherwood Industries Ltd. has no control over the installation of your stove, we grant no warranty
implied or stated for the installation or maintenance of your stove, therefore, Sherwood Industries Ltd.
assumes no responsibility for any consequential damage.
SAVE THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE