background image

SLIDER/DAMPER INSTALLATION INSTRUCTIONS

 

 

This is used to regulate the airflow through the pellet 
stove. 

 

A Qualified Service Technician or Installer should set the 
Slider Damper. 

 

The Slider Damper is pre set from the factory. The slider 
damper will be set and held in place with a 5/16” hex head 
screw. This screw will be tightened in the middle of the 
slot located in the slider damper plate. 

 

The slider damper is located behind the left side panel. 
To open the left side panel, undo the one screw located in 
the upper front corner of the cabinet side 

 

The combustion exhaust blower is a variable speed blower controlled by the heat output knob,(Dial a Fire).  This 
blower will decrease the vacuum pressure inside the stove and as the heat output knob is turned up.  The vacuum 
pressure inside the firebox will increase as the combustion exhaust blower increases in speed. 

 

SPECIAL NOTES: 

 

Pellet quality is a major factor in how the Pellet stove will operate. If the Pellets have a high moisture content or 
ash content the fire will be less efficient and has a higher possibility of the fire building up and creating clinkers. 
(hard ash build-up) 

 

If the fire should happen to go out and the Dial A Fire has been set on the lowest setting, the Slider Damper 
should be pushed in slightly decreasing the air in the firebox. 

 

If after long periods of burning the fire builds up and over flows the burn pot or there is a build up of clinkers This 
would be a sign that the pellet quality is poor and the slider damper must be pulled out to compensate.  

 

Pulling the slider damper out gives the fire more air. 

 

The easiest way to make sure that an efficient flame is achieved is to see the characteristics of the fire. 

• 

A tall and lazy flame with dark orange tips requires more air – Open slider / damper up. 

• 

A short and brisk flame, like a blowtorch, has too much air – Close slider / damper down. 

• 

If the flame is in the middle of these two characteristics with a bright yellow/orange, active flame then the air is 
set for proper operation. 

CLIP ON DOOR INSTALLATION 

 

1.  Unlatch door and swing open, remove door 

form unit. 

 

2.  Place door on a soft flat surface and remove 

the (4) screws (2 on each side) that hold the 
side trim pieces to the door. 

Side trim 

pieces 

2 screws per 

side

Inner door 

 

Clip on door (GOLD 

or NICKEL) 

 

3.  Undo all four screws that hold the outer clip on 

the door. 

 

4.  Install the new ( GOLD or NICKEL) clip on door 

using the four screws to fasten to the door. 

 

5.  Reinstall the side trim pieces using the screws 

that were removed from step 1. 

 

6.  Reinstall the door on the unit and latch with the 

handle provided. 

 

7

Содержание EF-IV I

Страница 1: ...PELLET STOVE EF IV i OWNERS TECHNICAL MANUAL SHERWOOD INDUSTRIES LTD 6782 OLDFIELD RD VICTORIA BRITISH COLUMBIA V8M 2A3...

Страница 2: ...4 INSTALLATION Vent Termination Requirements 13 Deciding Where To Locating Your Pellet Appliance 13 Removing Your New Stove From It s Pallet 14 Fireplace Dimensions 14 Masonry Fireplace Insert Install...

Страница 3: ...ndard 115 volts 60 hertz electrical outlet Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges This unit s maximum power requ...

Страница 4: ...E Since Sherwood Industries Ltd has no control over the quality of pellets that you use we assume no liability caused by the quality of wood pellets used P F I PELLET STANDARDS Fines 1 maximum through...

Страница 5: ...operation of the stove I KEEP ASH PAN FREE OF RAW FUEL DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN A fire in the ash pan could be the result J Fresh air intake is strongly recommended Failure...

Страница 6: ...he speed of the convection blower When you first start the stove it should be placed in the OFF position in order to heat the unit as quickly as possible Once the room has come up to temperature the c...

Страница 7: ...has been set on the lowest setting the Slider Damper should be pushed in slightly decreasing the air in the firebox If after long periods of burning the fire builds up and over flows the burn pot or...

Страница 8: ...operly inserted into the burn pot and the front tabs are in place in the firebox Place the liner back into the burn pot making sure that the ignitor hole in the liner is aligned with the ignitor tube...

Страница 9: ...ottom of the firebox loosen the screw on the disks and open this will allow vacuuming behind the firebox liners plates Removal of the fire box backing for BI annual cleaning 4 SEE PAGE 10 Open the doo...

Страница 10: ...onjunction with the pulses to the auger 3 START UP SWITCH When this momentary contact switch is pressed it will initiate the 15 minute start up cycle including the ignitor 4 DIAL A FIRE HEAT OUTPUT CO...

Страница 11: ...he blower s speed The module is controlled by a potentiometer in the Dial a Fire As the feed rate is increased the blower s speed is increased proportionally 9 TIMING CONTROL MODULE The timing control...

Страница 12: ...N C TEMPERATURE SENSOR IGNITOR SHUT DOWN SENSOR This sensor mounted on the exhaust channel will turn the ignitor off when the firebox temperature reaches 120 F 49 C 15 VACUUM SWITCH This safety device...

Страница 13: ...through a wall to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure To keep exhaust from causing a nuisance or hazard from exposing peo...

Страница 14: ...en the left and right side panels There are two wood screws that are holding the bottom of the stove to the pallet Remove the screws Close the side panels See PAGE 18 how to install the pedestal INSER...

Страница 15: ...ad 2 Lock fireplace damper in the open position 3 Install positive flue connector at the fireplace dampers 4 Connect a Tee or a 90 degree elbow to the exhaust pipe 5 Install flexible stainless steel l...

Страница 16: ...e mounting screws Make sure the top surround panel sits flat on the stove MAGNETIC STRIPS CORNER HARDWARE Sizing of face plates for FPI STANDARD 40 X 27 7 8 FPI PEDESTAL INSTALLATION The pedestal for...

Страница 17: ...mm in front of the appliance and at least the entire width of the appliance Side wall to unit A 6 INCHES 150 mm Back wall to unit B 2 INCH 50 mm Corner to unit C 2 INCH 50 mm Front of hearth pad to un...

Страница 18: ...FS comes with a pedestal that has to be attached prior to installation Remove the pedestal from the box Remove the ENVIROFIRE unit from the box Place the ENVIROFIRE unit on its back on the pallet Back...

Страница 19: ...ck leaving a minimum of 2 5 cm clearance from the back of the stove to the wall Seal the vent pipe to the thimble with high temperature silicone 10 The pipe must extend at least 12 30 cm away from the...

Страница 20: ...THROUGH WALL INSTALLATION 20...

Страница 21: ...e center of the fresh air intake pipe on the unit Match that center with the same point on the wall and cut a hole about 1 5 8 41 mm in diameter 5 Install the fresh air intake pipe 6 Install the tee w...

Страница 22: ...inish it by performing the following 9 Install a tee with clean out on the outside of the house 10 Install PL vent upward from the tee Make sure that you install support brackets to keep the vent stra...

Страница 23: ...om people sleep in Outside fresh air is mandatory OUTSIDE FRESH AIR CONNECTIONS Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes When connecting to an outsid...

Страница 24: ...ut off 9 The stove keeps going out NOTE All troubleshooting procedures should be carried out by qualified technicians or installers 1 The stove will not start Make sure the stove is plugged in and the...

Страница 25: ...tion blower against the wiring diagram If the convection motor will not run apply 115 V to the motor directly If the motor runs replace the fan controller If the motor does not run the convection blow...

Страница 26: ...st vacuum place a magnehelic gauge in the sensor end of the vacuum tube It should read 0 23 wc If the reading is good then replace the vacuum sensor If the auger motor still does not work then attempt...

Страница 27: ...ove goes out and leaves fresh unburned pellets or cigarette like ashes in the burn pot liner the fire is going out before the 120 F 49 C temperature sensor shuts the stove off Check to see that the sl...

Страница 28: ...WIRING DIAGRAM 28...

Страница 29: ...oden EF4i 144 GOLD BARS SET PIECES EF4i 029 DOOR LATCH W BOLT EF4i 152 THERMOSTAT INTERFACE EF4i 36 AUGER TIMER CONTROL EF4i 211 TAPPED CORNER BRACKET EF4i 037 POWER UP TIMER 20 017 FIREBOX LINER WOOL...

Страница 30: ...DIAL A FIRE EF4i 044 CONVECTION BLOWER EF4i 002 PHASE CONTROLLER EF4i 141 AUGER TIMER CONTROL EF4i 036 START UP TIMER EF4i 037 IEC POWER OUTLET PIN IGNITER SOCKET EF4i 128 IGNITER TEMP SENSOR 120 F 49...

Страница 31: ...60 FS RIGHT CABINET SIDE EF4i 143 CONTROL PANEL w DECAL EF4i 053 VACUUM PORT COVER IGNITION BURN POT EF4i 021 STAINLESS BURN POT LINER EF4i 024 FIREBOX LINER TOP BAFFLE EF4i 066 FIREBOX LINER W INSULA...

Страница 32: ...CAL MALFUNCTION ETC The limited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broke...

Отзывы: