background image

 

PARTS LIST 

 

EF4i-001 

AUGER MOTOR 

EF4i-100 

RETROFIT SLIDER KIT 

EF4i-002 CONVECTION 

BLOWER EF4i-103 

ASH 

SILL 

EF4i-007 COMBUSTION 

BLOWER EF4i-104 

HOPPER 

LID 

EF4i-008 

COMBUSTION MAIN IMPELLER 

EF4i-104A 

FPI HOPPER LID 

EF4i-009  

COMBUSTION COOLING IMPELLER 

EF4i-105 

ASH PAN LATCH FS ONLY 

EF4i-010 

EXHAUST TEMP SENSOR 120

°

EF4i-111 

FS STOVE TOP 

EF4i-011 

COMBUSTION MOUNTING GASKET 

EF4i-114 

FPI STOVE TOP 

EF4i-012 COMBUSTION 

BLOWER 

GASKET EF4i-118 

OWNERS 

MANUAL 

EF4i-013 

FAN TEMP SENSOR 160

°

 F 

EF4i-123 FRONT 

GRILL 

EF4i-015 

IGNITION TEMP SENSOR 120

°

 F 

EF4i-124 

SHOULDER BOLT, HRD BUSH, NUT 

EF4i-016 

HIGH LIMIT SENSOR 200

°

 F MR. 

EF4i-127 PIN 

IGNITOR 

EF4i-017 VACUUM 

SWITCH 

EF4i-130 

STEEL BRICK LINER 

EF4i-021 

IGNITION BURN POT 

EF4i-139 

FS PEDESTAL  (ASH PAN type) 

EF4i-024 

SS BURN POT LINER 

EF4i-141 

PHASE CONTROLLER 

EF4i-025 

AUGER 

EF4i-142 

FS LEFT CABINET SIDE 

EF4i-026 

AUGER BRASS BUSH AND PLATE 

EF4i-143 

FS RIGHT CABINET SIDE 

EF4i-028 

DOOR HANDLE (wooden) 

EF4i-144 

GOLD BARS SET  (PIECES) 

EF4i-029 

DOOR LATCH W/BOLT 

EF4i-152 THERMOSTAT 

INTERFACE 

EF4i-36 AUGER 

TIMER 

CONTROL EF4i-211 

TAPPED CORNER BRACKET 

EF4i-037 POWER 

UP 

TIMER 

20-017 

FIREBOX LINER WOOL INSULATION 

EF4i-041  

GREEN LIGHT 

20-034 

EF2/3/4 HALOGEN SOCKET 

EF4i-043 

START UP SWITCH 

20-040 

EF2/3/4 CONTROL PANEL DOOR 

EF4i-044 DIAL-A-FIRE 

 

 

EF4i-045 FAN 

CONTROLLER 

W/KNOB 

 

 

FE4i-047 FIREBOX 

LINER 

W/INSULATION 

 

 

EF4i-051 

HEAT EXCHANGER ROD W/KNOB 

 

 

EF4i-053 

CONTROL PANEL & DECAL  

 

 

EF4i-054 POWER 

CORD 

 

 

EF4i-O55 

ASH PAN GASKET 1/2 X 1/8” FLAT 

 

 

EF4i-056 

DOOR GASKET 3/4” FIRM X 80” 

 

 

EF4i-058 

WINDOW CHANNEL TAPE 

 

 

EF4i-059 

FPI HOPPER LID KNOB 

 

 

EF4i-060 

ASH PAN LATCH 

 

 

EF4i-062 GLASS 

SET 

 

 

EF4i-063 SLIDER 

DAMPER SPACER 

 

 

EF4i-064 

SLIDER DAMPER PLATE 

 

 

EF4i-065 

AUGER BRASS BUSHINGS (SET of 2) 

 

 

EF4i-066 

FIREBOX LINER TOP PLATE 

 

 

EF4i-069 

AUGER COLLAR SCREW SET 

 

 

EF4i-071 WIRING 

HARNESS 

 

 

EF4i-074 FPI 

PEDESTAL 

 

 

EF4i-076 

FPI SURROUND PANEL 40 X 27 7/8” 

 

 

EF4i-078 

OVERSIZE SURROUND PANEL 

 

 

EF4i-088A LOG 

SET 

 

 

EF4i-092 GOLD 

COMPLETE 

 

 

EF4i-093  

GOLD DOOR ONLY 

 

 

EF4i-094 

PAINTED DOOR COMPLETE 

 

 

EF4i-095 

PAINTED DOOR ONLY 

 

 

EF4i-096 

DOOR LATCH AND HINGE COVERS 

 

 

EF4i-097 BACK 

GRILL 

 

 

 

29

Содержание EF-IV I

Страница 1: ...PELLET STOVE EF IV i OWNERS TECHNICAL MANUAL SHERWOOD INDUSTRIES LTD 6782 OLDFIELD RD VICTORIA BRITISH COLUMBIA V8M 2A3...

Страница 2: ...4 INSTALLATION Vent Termination Requirements 13 Deciding Where To Locating Your Pellet Appliance 13 Removing Your New Stove From It s Pallet 14 Fireplace Dimensions 14 Masonry Fireplace Insert Install...

Страница 3: ...ndard 115 volts 60 hertz electrical outlet Be careful that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges This unit s maximum power requ...

Страница 4: ...E Since Sherwood Industries Ltd has no control over the quality of pellets that you use we assume no liability caused by the quality of wood pellets used P F I PELLET STANDARDS Fines 1 maximum through...

Страница 5: ...operation of the stove I KEEP ASH PAN FREE OF RAW FUEL DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN A fire in the ash pan could be the result J Fresh air intake is strongly recommended Failure...

Страница 6: ...he speed of the convection blower When you first start the stove it should be placed in the OFF position in order to heat the unit as quickly as possible Once the room has come up to temperature the c...

Страница 7: ...has been set on the lowest setting the Slider Damper should be pushed in slightly decreasing the air in the firebox If after long periods of burning the fire builds up and over flows the burn pot or...

Страница 8: ...operly inserted into the burn pot and the front tabs are in place in the firebox Place the liner back into the burn pot making sure that the ignitor hole in the liner is aligned with the ignitor tube...

Страница 9: ...ottom of the firebox loosen the screw on the disks and open this will allow vacuuming behind the firebox liners plates Removal of the fire box backing for BI annual cleaning 4 SEE PAGE 10 Open the doo...

Страница 10: ...onjunction with the pulses to the auger 3 START UP SWITCH When this momentary contact switch is pressed it will initiate the 15 minute start up cycle including the ignitor 4 DIAL A FIRE HEAT OUTPUT CO...

Страница 11: ...he blower s speed The module is controlled by a potentiometer in the Dial a Fire As the feed rate is increased the blower s speed is increased proportionally 9 TIMING CONTROL MODULE The timing control...

Страница 12: ...N C TEMPERATURE SENSOR IGNITOR SHUT DOWN SENSOR This sensor mounted on the exhaust channel will turn the ignitor off when the firebox temperature reaches 120 F 49 C 15 VACUUM SWITCH This safety device...

Страница 13: ...through a wall to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure To keep exhaust from causing a nuisance or hazard from exposing peo...

Страница 14: ...en the left and right side panels There are two wood screws that are holding the bottom of the stove to the pallet Remove the screws Close the side panels See PAGE 18 how to install the pedestal INSER...

Страница 15: ...ad 2 Lock fireplace damper in the open position 3 Install positive flue connector at the fireplace dampers 4 Connect a Tee or a 90 degree elbow to the exhaust pipe 5 Install flexible stainless steel l...

Страница 16: ...e mounting screws Make sure the top surround panel sits flat on the stove MAGNETIC STRIPS CORNER HARDWARE Sizing of face plates for FPI STANDARD 40 X 27 7 8 FPI PEDESTAL INSTALLATION The pedestal for...

Страница 17: ...mm in front of the appliance and at least the entire width of the appliance Side wall to unit A 6 INCHES 150 mm Back wall to unit B 2 INCH 50 mm Corner to unit C 2 INCH 50 mm Front of hearth pad to un...

Страница 18: ...FS comes with a pedestal that has to be attached prior to installation Remove the pedestal from the box Remove the ENVIROFIRE unit from the box Place the ENVIROFIRE unit on its back on the pallet Back...

Страница 19: ...ck leaving a minimum of 2 5 cm clearance from the back of the stove to the wall Seal the vent pipe to the thimble with high temperature silicone 10 The pipe must extend at least 12 30 cm away from the...

Страница 20: ...THROUGH WALL INSTALLATION 20...

Страница 21: ...e center of the fresh air intake pipe on the unit Match that center with the same point on the wall and cut a hole about 1 5 8 41 mm in diameter 5 Install the fresh air intake pipe 6 Install the tee w...

Страница 22: ...inish it by performing the following 9 Install a tee with clean out on the outside of the house 10 Install PL vent upward from the tee Make sure that you install support brackets to keep the vent stra...

Страница 23: ...om people sleep in Outside fresh air is mandatory OUTSIDE FRESH AIR CONNECTIONS Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes When connecting to an outsid...

Страница 24: ...ut off 9 The stove keeps going out NOTE All troubleshooting procedures should be carried out by qualified technicians or installers 1 The stove will not start Make sure the stove is plugged in and the...

Страница 25: ...tion blower against the wiring diagram If the convection motor will not run apply 115 V to the motor directly If the motor runs replace the fan controller If the motor does not run the convection blow...

Страница 26: ...st vacuum place a magnehelic gauge in the sensor end of the vacuum tube It should read 0 23 wc If the reading is good then replace the vacuum sensor If the auger motor still does not work then attempt...

Страница 27: ...ove goes out and leaves fresh unburned pellets or cigarette like ashes in the burn pot liner the fire is going out before the 120 F 49 C temperature sensor shuts the stove off Check to see that the sl...

Страница 28: ...WIRING DIAGRAM 28...

Страница 29: ...oden EF4i 144 GOLD BARS SET PIECES EF4i 029 DOOR LATCH W BOLT EF4i 152 THERMOSTAT INTERFACE EF4i 36 AUGER TIMER CONTROL EF4i 211 TAPPED CORNER BRACKET EF4i 037 POWER UP TIMER 20 017 FIREBOX LINER WOOL...

Страница 30: ...DIAL A FIRE EF4i 044 CONVECTION BLOWER EF4i 002 PHASE CONTROLLER EF4i 141 AUGER TIMER CONTROL EF4i 036 START UP TIMER EF4i 037 IEC POWER OUTLET PIN IGNITER SOCKET EF4i 128 IGNITER TEMP SENSOR 120 F 49...

Страница 31: ...60 FS RIGHT CABINET SIDE EF4i 143 CONTROL PANEL w DECAL EF4i 053 VACUUM PORT COVER IGNITION BURN POT EF4i 021 STAINLESS BURN POT LINER EF4i 024 FIREBOX LINER TOP BAFFLE EF4i 066 FIREBOX LINER W INSULA...

Страница 32: ...CAL MALFUNCTION ETC The limited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broke...

Отзывы: