background image

PARTS LIST 

 
EF-001 

AUGER MOTOR 

EF-088A 

LOG SET   (20-036) 

EF-002 CONVECTION 

BLOWER 

EF-091 

FPI BRASS TRIM 

EF-004 

CONVECTION BLOWER IMPELLER 

EF-092 

EF3Bi GOLD DOOR COMPLETE 

EF-007 

COMBUSTION BLOWER COMPLETE 

EF-093 

EF3Bi GOLD DOOR ONLY 

EF-008 

COMBUSTION MAIN IMPELLER 

EF-094 

EF3Bi PAINTED DOOR COMPLETE 

EF-009 

COMBUSTION COOLING IMPELLER 

EF-095 

EF3Bi PAINTED DOOR ONLY 

EF-010 

EXHAUST TEMP SENSOR 140

°

 F 

EF-097 BACK 

GRILL 

EF-011 

COMBUSTION BLOWER MOUNTING 
GASKET (RECTANGULAR) 

EF-100 

RETROFIT SLIDER KIT 

EF-012 

COMBUSTION BLOWER HOUISING 
GASKET (CIRCULAR) 

EF-102 

BIH KIT (NEW STYLE) 

EF-013 

FAN TEMP SENSOR 160

°

 F 

EF-104 

EF 2/3 HOPERLID W/HANDLE 

EF-015 

IGNTION TEMP SENSOR 120

°

 F 

EF-111 

EF3Bi FS STOVE TOP 

EF-016 

HIGH LIMIT SENSOR 200

°

 F MR. 

EF-114 

EF3Bi FPI STOVE TOP 

EF-017 

VACUUM SWITCH 

EF-118 

EF3Bi OWNERS MANUAL 

EF-018  

VACUUM HOSE 

EF-121 

EF3Bi ASH SILL 

EF-021 

IGNITION BURN POT 

EF-122 

EF2/3 FPI/BIH HOPPER COVER 

EF-024  

SS BURN POT LINER 

EF-123 

EF3Bi FRONT GRILL 

EF-025 

AUGER 

EF-124 

SHOULDER BOLT, HRD BUSH, NUT 

EF-026 

AUGER BRASS BUSHING AND PLATE 

EF-126 FIREBOX 

CERAMOC 

WOOL INSULATION 

EF-028 

EF3Bi DOOR HANDLE 

EF-127 

PIN IGNITER 

EF-029 

EF3Bi DOOR HANDLE BOLT 

EF-129 

EF3Bi STEEL BRICK LINER 

EF-036 

AUGER TIMER CONTROL 

EF-133 

EF3Bi RIGHT CABINET SIDE 

EF-037 

EF3 POWER UP TIMER CONTROL 

EF-134 

EF3Bi LEFT CABINET SIDE 

EF-041 

GREEN LIGHT 

EF-141 

HOPPER LID HINGE 

EF-043 

EF 3 START UP SWITCH 

EF-150 

DECORATIVE TRIVET  PAINTED 

EF-044 

DIAL-A-FIRE 

EF-151 

DECORATIVE TRIVET GOLD 

EF-045 

FAN CONTROLLER W/KNOB 

EF-152 

THERMOSTA INTERFACE 

EF-047 

EF3Bi FIREBOX LINER W/INSUALTION 

EF-161 

COMBUSTION BLOWER MOTOR ONLY 

EF-050 

SLIDER DAMPER ROD W/KNOB 

EF-184A 

FRONT GRILL LOUVER BRASS 

EF-051 

HEAT EXCHANGER ROD W/KNOB 

EF-193 

DOOR HINGE BRACKET 

EF-054 

POWER CORD 

EF-194A 

FIREBOX CLEANING PORT COVERS 

EF-055 

EF 1/2” ROUND ASH PAN GASKET 24” 

EF-202 

EF3Bi FPI HOPPER LID W/KNOB 

EF-056 

EF3Bi 5/8” DOOR GASKET- 50” 

EF-205 

FAN CONTROLLER KNOB 

EF-062 

EF3Bi GLASS SET 

EF-211 

FPI TAPPED CORNER BRACKET 

EF-064 

SLIDER DAMPER PLATE 

20-034 

EF2/3/4 HALOGEN SOCKET 

EF-065 

AUGER BRASS BUSHING (SET of 2) 

20-036 

LOG SET 

EF-066 

FIREBOX LINER TOP PLATE 

 

 

EF-067 DIAL-A-FIRE 

KNOB 

 

 

EF-068 

HEAT EXCHANGER KNOB 

 

 

EF-069 

AUGER COLLAR SET SCREW 

 

 

EF-070 

SLIDER DAMPER KNOB 

 

 

EF-071 

EF3Bi WIRING HARNESS 

 

 

EF-071A 

EF3Bi FPI WIRING HARNESS 

 

 

EF-073 

EF3Bi FS PEDESTAL 

 

 

EF-074 FPI 

PEDESTAL 

 

 

EF-074A BIH 

PEDESTAL 

 

 

EF-076 

FPI PANEL 40” X 30 1/4” 

 

 

EF-077A 

BIH PANEL 36” X 32 9/16” 

 

 

EF-078 

FPI OVERSIZE PANEL 46 X 33 

 

 

EF-079 

BIH OVERSIZE PANEL 46” X 34 3/4” 

 

 

 

 

 

 

 

28

Содержание EF-III BAY I BIH

Страница 1: ...1 SHERWOOD INDUSTRIES LTD 6782 OLDFIELD ROAD VICTORIA BRITISH COLUMBIA V8M 2A3 PELLET STOVE EF III BAY i OWNERS TECHNICAL MANUAL MODELS FS FPI and BIH...

Страница 2: ...2 Vent Termination Requirements 12 Removing Your New Stove From It s Pallet 13 Masonry Fireplace Insert Installation 14 Assembling the Face Plate for the FPI BIH Models 15 Model BIH Recommended Framin...

Страница 3: ...d on the left side of the stove It is advisable to clean the exhaust vent bi annually or every two tons of pellets The grounded electrical cord should be connected to a standard 115 volts 60 hertz ele...

Страница 4: ...TOVE Since Sherwood Industries Ltd has no control over the quality of pellets that you use we assume no liability caused by the quality of wood pellets used P F I PELLET STANDARDS Fines 1 maximum thro...

Страница 5: ...installed in Mobile Homes as well as Air Tight homes J GOLD BARS Please clean all fingerprints off of all gold parts before firing the unit each time Fingerprints etc can become etched into the gold...

Страница 6: ...went out return to step number 2 and re light the stove DIAL A FIRE HEAT OUTPUT KNOB 6 Adjusting the blower speed control knob will vary the rate of airflow into the room by varying the speed of the c...

Страница 7: ...de panel and tighten screws after placing the rod through the panel Screw the knob onto the slider OPERATION On the low heat output settings push the slider all the way in On the high heat output pull...

Страница 8: ...and burn pot liner open the door using the door handle provided located on the left hand side of the stove swing the door open Lift the liner from the burn pot lift the burn pot from the firebox by g...

Страница 9: ...ng it into one side panel then across into the other panel Screw rod in place Re install steel brick liner and screw in place Replace top baffle EXHAUST VENT Soot and Flyash Formation and Need for Rem...

Страница 10: ...anger tubes and back into the room The units sealed system keeps the room air separate from the combustion air The convection fan controller controls this fan s speed 6 EXHAUST COMBUSTION BLOWER This...

Страница 11: ...F 49 C N C TEMPERATURE SENSOR IGNITOR SHUT DOWN SENSOR This sensor mounted on the exhaust channel will turn the ignitor off when the exhaust temperature reaches 120 F 49 C 14 VACUUM SWITCH This safety...

Страница 12: ...a wall to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure To keep exhaust from causing a nuisance or hazard from exposing people or s...

Страница 13: ...eft and right side panels There are two wood screws that are holding the bottom of the stove to the pallet Remove the screws Close the side panels See PAGE 18 how to install the pedestal INSERT MODEL...

Страница 14: ...nstalled with a continuous chimney liner of 3 or 4 diameter extending from the fireplace insert to the top of the chimney The liner must conform to type 3 requirements of CAN ULC S635 6 Recommended In...

Страница 15: ...Insert each side panel anchor screw through the top panel into the corresponding side panel holes and tighten 3 Assemble the brass frame using the corner hardware and screws supplied in the face plate...

Страница 16: ...IBLES This unit includes a 3 75 mm pedestal and surrounding faceplates The part of the unit behind the faceplate can be enclosed with combustible material Model BIH has 1 25 mm standoffs to establish...

Страница 17: ...mm Mantle Hearth Mount 8 INCHES Combustible flooring underneath the unit and extending 6 INCHES 150 mm to the sides and front must be protected by a non combustible material ALCOVE DIMENSIONS Minimum...

Страница 18: ...ation Remove the pedestal from the box Remove the ENVIROFIRE heater form the box Place the unit on its back making sure not to damage the wiring Back off the screws on the base install the pedestal ov...

Страница 19: ...exhaust vent pipe to the exhaust pipe on the stove 10 All Joints in the vent system shall be fastened with 3 three screws Seal the connection with high temperature silicone 11 Push the stove straight...

Страница 20: ...THROUGH WALL INSTALLATION 1 20...

Страница 21: ...center of the fresh air intake pipe on the unit Match that center with the same point on the wall and cut a hole about 1 5 8 41 mm in diameter 5 Install the fresh air intake pipe 6 Install the tee wit...

Страница 22: ...n finish it by performing the following 9 Install a tee with clean out on the outside of the house 10 Install PL vent upward from the tee Make sure that you install support brackets to keep the vent s...

Страница 23: ...irtight homes or manufactured homes OUTSIDE FRESH AIR CONNECTIONS A Fresh air intake is strongly recommended Failure to install Intake air may result in improper combustion as well as the unit smoking...

Страница 24: ...inged side panels held tight with two screws With the stove unplugged examine all connections Make sure they are firmly connected and that there are no exposed wires touching the stove except the chas...

Страница 25: ...is operating Make sure the dial a fire is turned on Unplug the stove and open the side and back panels Check all the connections to the auger motor auger dial a fire vacuum sensor 200 F 93 C temperatu...

Страница 26: ...own wires from the sensor The unit should shut down right away as long as the start button was not pressed within 15 minutes of this test If the stove shuts down within 15 minutes replace the 140 F 60...

Страница 27: ...WIRING DIAGRAM 27...

Страница 28: ...R HANDLE BOLT EF 129 EF3Bi STEEL BRICK LINER EF 036 AUGER TIMER CONTROL EF 133 EF3Bi RIGHT CABINET SIDE EF 037 EF3 POWER UP TIMER CONTROL EF 134 EF3Bi LEFT CABINET SIDE EF 041 GREEN LIGHT EF 141 HOPPE...

Страница 29: ...002 AUGER TIMER CONTROL EF 036 START SWITCH EF 043 CONTROL PANEL W DECAL EF 053 HIGH LIMIT SENSOR 200 F 93 C MANUAL RESET EF 016 IGNITER TEMP SENSOR 120 F 49 C EF 015 FAN CONTROLLER EF 045 GREEN LIGHT...

Страница 30: ...F 121 EF3Bi DOOR HANDLE EF 028 EF3Bi FRONT GRILL EF 123 FIREBOX CLEANING PORT COVERS EF 194 EF3Bi FS RIGHT CABINET SIDE EF 133 EF3Bi FPI SIDE RAILS R L EF 145 EF3Bi FS HOPPER SIDE RAIL EF 143 ASH PAN...

Страница 31: ...mited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broken as a result of mishandli...