background image

ELECTRICAL COMPONENT FUNCTIONS 

 

The following is a list of electrical components and their functions on the ENVIROFIRE EF-IIIi Bay pellet stove. 
 

1. 

CONVECTION FAN CONTROLLER 

 
This controller is responsible for varying the speed of the convection blower.  The stove does have a fan control 
over-ride.  Should the convection blower be set on low and dial-a-fire set on high, the convection blower will by-
pass the fan controller and go to high.  This will cool the stove until control is given back to the fan controller.  To 
eliminate possible cycling of the convection blower turn up the fan speed proportionately to the dial-a-fire. 
 

2. 

AUGER PULSE LIGHT 

 
This light will flash in conjunction with the pulses to the auger. 
 

3. START-UP 

SWITCH 

 
When this momentary contact switch is pressed it will initiate a 15 minute start-up cycle including the ignitor. 
 

4. 

DIAL-A-FIRE (HEAT OUTPUT CONTROL) 

 
This unit is responsible for controlling the timing of the auger motor.  When turned clockwise it will cause the OFF 
time between auger pulses to shorten, resulting in more heat output and pellet consumption.  Turn the knob 
counter-clockwise and the reverse will happen.  When it is turned fully counter-clockwise past the click, the auger 
motor will be off. 
 

5. CONVECTION 

BLOWER 

 
This blower fan (mounted on the right side of the stove) draws room airs from the back of the stove and passes 
the air through the heat exchanger tubes and back into the room.  The units sealed system keeps the room air 
separate from the combustion air. The convection fan controller controls this fan’s speed. 
 

6. EXHAUST/COMBUSTION BLOWER 

 
This constant speed fan (mounted on the left side of the stove) is responsible for drawing the outside fresh air into 
the combustion chamber for burning.  The hot air then continues to be drawn over the heat exchanger tubes and 
into the exhaust channel.  It is then pushed out through the exhaust system. 
 

7. 

AUGER MOTOR AND AUGER 

 
The 1 rpm auger motor is responsible for turning the auger, which in turn transports pellets to be dropped into the 
burn pot.  The auger motor’s control is handled by the timing control module and Dial-A-Fire. 

 

8. 

TIMING CONTROL MODULE 

 
The timing control module is mounted uppermost, on the right rear pillar of the stove.  The module controls the 
switching of power to the auger.  The module’s switching duty cycle is controlled by the dial-a-fire. 
 

9. START-UP 

TIMER 

 

This 15 minute one-shot timer bypasses the 140

°

F (60

°

C) temperature sensor allowing the stove to operate when 

cold.  The timing cycle is initiated by pressing the start-up switch.  The 15 minute timer is

 

located right under the 

timing control module on the right side pillar.  This unit is also responsible for initiating the ignition cycle. 
 

10. 200

°

F (93

°

C) MANUAL RESET TEMPERATURE SENSOR 

 
This sensor (located on the right side firewall) has a red push button located in its center. This is a safety device.  
In the event that the convection blower fails, this sensor will overheat and shut off power to the auger motor. 
 

 

10

Содержание EF-III BAY I BIH

Страница 1: ...1 SHERWOOD INDUSTRIES LTD 6782 OLDFIELD ROAD VICTORIA BRITISH COLUMBIA V8M 2A3 PELLET STOVE EF III BAY i OWNERS TECHNICAL MANUAL MODELS FS FPI and BIH...

Страница 2: ...2 Vent Termination Requirements 12 Removing Your New Stove From It s Pallet 13 Masonry Fireplace Insert Installation 14 Assembling the Face Plate for the FPI BIH Models 15 Model BIH Recommended Framin...

Страница 3: ...d on the left side of the stove It is advisable to clean the exhaust vent bi annually or every two tons of pellets The grounded electrical cord should be connected to a standard 115 volts 60 hertz ele...

Страница 4: ...TOVE Since Sherwood Industries Ltd has no control over the quality of pellets that you use we assume no liability caused by the quality of wood pellets used P F I PELLET STANDARDS Fines 1 maximum thro...

Страница 5: ...installed in Mobile Homes as well as Air Tight homes J GOLD BARS Please clean all fingerprints off of all gold parts before firing the unit each time Fingerprints etc can become etched into the gold...

Страница 6: ...went out return to step number 2 and re light the stove DIAL A FIRE HEAT OUTPUT KNOB 6 Adjusting the blower speed control knob will vary the rate of airflow into the room by varying the speed of the c...

Страница 7: ...de panel and tighten screws after placing the rod through the panel Screw the knob onto the slider OPERATION On the low heat output settings push the slider all the way in On the high heat output pull...

Страница 8: ...and burn pot liner open the door using the door handle provided located on the left hand side of the stove swing the door open Lift the liner from the burn pot lift the burn pot from the firebox by g...

Страница 9: ...ng it into one side panel then across into the other panel Screw rod in place Re install steel brick liner and screw in place Replace top baffle EXHAUST VENT Soot and Flyash Formation and Need for Rem...

Страница 10: ...anger tubes and back into the room The units sealed system keeps the room air separate from the combustion air The convection fan controller controls this fan s speed 6 EXHAUST COMBUSTION BLOWER This...

Страница 11: ...F 49 C N C TEMPERATURE SENSOR IGNITOR SHUT DOWN SENSOR This sensor mounted on the exhaust channel will turn the ignitor off when the exhaust temperature reaches 120 F 49 C 14 VACUUM SWITCH This safety...

Страница 12: ...a wall to create some natural draft to prevent the possibility of smoke or odor during appliance shut down or power failure To keep exhaust from causing a nuisance or hazard from exposing people or s...

Страница 13: ...eft and right side panels There are two wood screws that are holding the bottom of the stove to the pallet Remove the screws Close the side panels See PAGE 18 how to install the pedestal INSERT MODEL...

Страница 14: ...nstalled with a continuous chimney liner of 3 or 4 diameter extending from the fireplace insert to the top of the chimney The liner must conform to type 3 requirements of CAN ULC S635 6 Recommended In...

Страница 15: ...Insert each side panel anchor screw through the top panel into the corresponding side panel holes and tighten 3 Assemble the brass frame using the corner hardware and screws supplied in the face plate...

Страница 16: ...IBLES This unit includes a 3 75 mm pedestal and surrounding faceplates The part of the unit behind the faceplate can be enclosed with combustible material Model BIH has 1 25 mm standoffs to establish...

Страница 17: ...mm Mantle Hearth Mount 8 INCHES Combustible flooring underneath the unit and extending 6 INCHES 150 mm to the sides and front must be protected by a non combustible material ALCOVE DIMENSIONS Minimum...

Страница 18: ...ation Remove the pedestal from the box Remove the ENVIROFIRE heater form the box Place the unit on its back making sure not to damage the wiring Back off the screws on the base install the pedestal ov...

Страница 19: ...exhaust vent pipe to the exhaust pipe on the stove 10 All Joints in the vent system shall be fastened with 3 three screws Seal the connection with high temperature silicone 11 Push the stove straight...

Страница 20: ...THROUGH WALL INSTALLATION 1 20...

Страница 21: ...center of the fresh air intake pipe on the unit Match that center with the same point on the wall and cut a hole about 1 5 8 41 mm in diameter 5 Install the fresh air intake pipe 6 Install the tee wit...

Страница 22: ...n finish it by performing the following 9 Install a tee with clean out on the outside of the house 10 Install PL vent upward from the tee Make sure that you install support brackets to keep the vent s...

Страница 23: ...irtight homes or manufactured homes OUTSIDE FRESH AIR CONNECTIONS A Fresh air intake is strongly recommended Failure to install Intake air may result in improper combustion as well as the unit smoking...

Страница 24: ...inged side panels held tight with two screws With the stove unplugged examine all connections Make sure they are firmly connected and that there are no exposed wires touching the stove except the chas...

Страница 25: ...is operating Make sure the dial a fire is turned on Unplug the stove and open the side and back panels Check all the connections to the auger motor auger dial a fire vacuum sensor 200 F 93 C temperatu...

Страница 26: ...own wires from the sensor The unit should shut down right away as long as the start button was not pressed within 15 minutes of this test If the stove shuts down within 15 minutes replace the 140 F 60...

Страница 27: ...WIRING DIAGRAM 27...

Страница 28: ...R HANDLE BOLT EF 129 EF3Bi STEEL BRICK LINER EF 036 AUGER TIMER CONTROL EF 133 EF3Bi RIGHT CABINET SIDE EF 037 EF3 POWER UP TIMER CONTROL EF 134 EF3Bi LEFT CABINET SIDE EF 041 GREEN LIGHT EF 141 HOPPE...

Страница 29: ...002 AUGER TIMER CONTROL EF 036 START SWITCH EF 043 CONTROL PANEL W DECAL EF 053 HIGH LIMIT SENSOR 200 F 93 C MANUAL RESET EF 016 IGNITER TEMP SENSOR 120 F 49 C EF 015 FAN CONTROLLER EF 045 GREEN LIGHT...

Страница 30: ...F 121 EF3Bi DOOR HANDLE EF 028 EF3Bi FRONT GRILL EF 123 FIREBOX CLEANING PORT COVERS EF 194 EF3Bi FS RIGHT CABINET SIDE EF 133 EF3Bi FPI SIDE RAILS R L EF 145 EF3Bi FS HOPPER SIDE RAIL EF 143 ASH PAN...

Страница 31: ...mited warranty covers defects in materials and workmanship as long as the products has been installed according to the manual s instruction If the product is damaged or broken as a result of mishandli...

Отзывы: