23
The ENVIRO
E44 may be installed and vented into any solid fuel fireplace that has been installed in
accordance with the National, Provincial/State and local building codes and has been constructed of non-
combustible materials. Before starting, refer to please reference the information in Table 5 and Figures
26 & 27.
An approved chimney liner and rain cap must be used. A throat connector or flashing (Figure 27)
must be
installed to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s
instructions that accompany the chimney liner kit. Use double walled aluminum flex vent from either M&G
DuraVent DirectVent Pro or ICC Excel Direct (see table 6). If necessary, remove the vent collar plate from
the top of the insert and connect it securely to the liner with sheet metal screws.
Check for any tears in the liner at this point. IMPORTANT: The screws that hold the vent collar plate in its
approved position must be installed.
Initial Installation
QUALIFIED INSTALLERS ONLY
NOTE: If the E44 unit is pulled out of its installation, and the vent air intake system is disconnected
for any reason, ensure that the vent-air intake pipes are re-sealed with high-temperature sealant and
reconnected with three (3) sheet metal screws evenly spaced.
The height for the vent must be between 10 ft (3.05 m) and 40 ft (12 m) from
the top of the unit to the bottom of the termination
Install a sealed vent cap to prevent leakage of room air up through chimney.
The intake and the exhaust are 3" (76mm).
Measure the height of the chimney beforehand and purchase the appropriate
venting. Never attempt to over-stretch a flexible liner to accommodate the
height of the chimney. Every joint in the venting must be secured with three (3)
#8 x 3/8” HWH sheet metal screws and an appropriate sealant (either silicone
or stove cement).
The flue damper must be fully blocked using a non-combustable seal off plate;
the smoke shelves, shields and baffles may be removed if attached by
mechanical fasteners.
The air intake liner must extend a minimum of 12” above the seal off plate.
The exhaust liner must connect to the termination.
The fireplace and fireplace chimney must be clean, in good working order and
constructed of non-combustible materials.
Make sure that all chimney cleanouts are tight fitting and will not permit air to
leak into the chimney. It must be completely sealed.
The height for the vent must be between 10 ft (3.05 m) and 40 ft (12 m) from
the top of the unit to the bottom of the termination.
Install a sealed vent cap to prevent leakage of room air up through chimney.
The intake and the exhaust are 3" (76mm).
Measure the height of the chimney beforehand and purchase the appropriate
venting. Never attempt to over-stretch a flexible liner to accommodate the
height of the chimney. Every joint in the venting must be secured with three (3)
#8 x 3/8” HWH sheet metal screws and an appropriate sealant (either silicone
or stove cement).
The flue damper can be fully blocked open or removed for installation of the
unit; the smoke shelves, shields and baffles may be removed if attached by
mechanical fasteners.
The fireplace and fireplace chimney must be clean, in good working order and
constructed of non-combustible materials.
Make sure that all chimney cleanouts are tight fitting and will not permit air to
leak into the chimney.
Refractory, glass doors, screen rails, screen mesh and log grates can be
removed from the fireplace before installing the unit.
12”
Figure 26:
Installation of E44