background image

43

Parts List

Reference 

Number

Part Description

Part Number

1

E44 DV Flue Adaptor Bottom Gasket

50-2516

-

E44I Owner’s Manual

50-2628

-

IPI LP Conversion Stepper Motor Only

50-3753

-

IPI NG Conversion Stepper Motor Only

50-3870

2

Door Release Tool

50-2510

-

Ceramic Wool Embers Only

50-893

3

Domestic Power Cord (115V)

EC-042

4

Heyco Strain Relief

EC-044

5

 Pilot Shield

50-2691

6

PSE IPI Pilot Assembly (2021)

50-4058

-

IPI LP Pilot Orifice (2021)

50-4080

7

E44 H-Burner Tube

50-3654

8

885 Proflame IPI Valve NG

50-2682

9

  Proflame 2 Battery Holder (0.584.103)

50-3204

-

Battery Holder Wire Harness

50-3305

10

  Proflame 2 IFC 

50-3791

-

IFC Wire Harness (0.584.924)

50-3030

-

IFC ON/OFF Jumper Only

50-3205

11

Proflame 2 Transmitter (TMFSLA)

50-3265

12

E44 Door Complete

50-2685

13

E44 Glass C/W Gasket (30.625” x 22.25”)

50-2686

14

Dual Bulb Door Gasket (10ft)

50-634

15

E44 Replacement Safety Screen

50-3074

16

Convection Fan Only

50-2493

17

E44 Door Latch Mechanism (Set of 2) 

50-2687

18

Brick Liner Set - E44

50-2664

-

 Porcelain Liner Set - E44

50-2577

-

 Fluted Liner Set - E44

50-3310

-

 Herringboine Liner Set - E44

50-3663

-

 E44 Traditional Logset (10 pcs)

50-3633

-

 E44 Birch Logset (10 pcs)

50-3634

-

 12 oz. Can of Metallic Black Touch Up Paint

PAINT-12-MB

Note: For E44ID specific replacement parts refer to the Dexen user manual supplied 

Содержание E44I

Страница 1: ...G I S T R A T I O N e n v i r o c o m w a r r a n t y E44I E44ID G A S I N S E R T L O G S E T w I P I V a l v e WARNING If the information in this manual is not followed exactly a fire or explosion...

Страница 2: ...ll your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali...

Страница 3: ...must be performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFP...

Страница 4: ...The Painted Surfaces 17 Glass Door Removal 17 Removing Valve Cover 18 Cleaning The Firebox 18 Replacing The Glass 18 Check Pilot and Burner Flames 18 Fuel Conversion 19 Initial Installation 21 Clearan...

Страница 5: ...ion 34 Firebox Liner and Burner Tube Removal 35 Log Set and Ember Installation Traditional Birch 36 TroubleShooting 40 Diagnostic Flash Codes does not apply to E44ID models 40 Parts List 43 Parts Diag...

Страница 6: ...with either natural or propane gases See rating label Is not for use with solid fuels Is approved for bedroom or bed sitting room IN CANADA must be installed with a permanent wall thermostat for bedro...

Страница 7: ...need for each surround panel Refer to Secondary Installation page 31 for instructions about changing the extension setting 29 33 21 06 31 03 45 00 28 75 25 38 38 25 46 33 31 04 22 76 20 99 7 93 24 77...

Страница 8: ...ry Surround Extruded Surround Height 30 1 8 765 mm 30 1 8 765 mm 30 1 8 765 mm Width 45 1143 mm 45 1143 mm 45 1143 mm Trimmable Surround Height Width 36 914mm 55 1397mm Base Shelf Base Shelf Riser Hei...

Страница 9: ...y part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERAT...

Страница 10: ...in order to accommodate different climates and venting arrangements Start the pilot and then the burner Make sure the pilot flame is burning normally and none of the burner ports are plugged Let the...

Страница 11: ...A Mode Key is provided to Index between the features and a Thermostat Key is used to turn on off or index through Thermostat functions Figure 5 6 Figure 5 Proflame 2 Transmitter System Description Th...

Страница 12: ...is powered by four 4 AA type batteries The IFC accepts commands via radio frequency from the Transmitter to operate the appliance in accordance with the particular Proflame system configuration The Ba...

Страница 13: ...tructions Turn off the Appliance Press the ON OFF Key on the Transmitter The Transmitter LCD display will only show the room temperature and Icon see Figure 9 A single beep from the IFC confirms recep...

Страница 14: ...will confirm reception of the command Figure 11 Remote Control s Flame Levels Flame Off Flame Level 1 Flame Level 5 Maximum Flame Level Flame Off Flame Level 1 Flame Level 5 Maximum Flame Level Fan C...

Страница 15: ...is not used on the E44 and can be disregarded Key lock This function will lock the keys to avoid unsupervised operation To activate this function press the MODE and UP keys at the same time and the a...

Страница 16: ...Keep away from the appliance burner when operating the remote system Operating Instructions WARNING Shock Hazard Can cause severe injury or death This device is powered by line voltage Do not try to...

Страница 17: ...w dust and lint to cling to the glass surface Initial paint curing of the appliance can leave a slight film on the glass The glass will need cleaning after the fireplace has cooled off from the first...

Страница 18: ...r assembly to prevent personal injury Do not operate with the glass front removed cracked or broken Removal and replacement of the glass from the door must be done by a licensed or qualified service p...

Страница 19: ...amaged or are missing contact your dealer distributor or courier company to have them replaced before starting this installation Maintenance And Service Conversion Kit Installation 1 Turn the unit off...

Страница 20: ...has been installed at an altitude higher than 2000ft 610m it is required to de rate the unit accordingly In the USA The appliance may be installed at higher altitudes Please refer to your American Gas...

Страница 21: ...l in front of the unit If installed where the hearth is flush with the combustible flooring there must be a minimum of 18 457 mm of non combustible material in front of the unit Minimum ceiling cleara...

Страница 22: ...of a standard 3 vent and must be fastened directly to the vent with three screws The exhaust vent and air intake are both located on the top of the unit Check periodically that the vents are unrestric...

Страница 23: ...r the vent must be between 10 ft 3 05 m and 40 ft 12 m from the top of the unit to the bottom of the termination Install a sealed vent cap to prevent leakage of room air up through chimney The intake...

Страница 24: ...sure that all chimney cleanouts are tight fitting and will not permit air to leak into the chimney It must be completely sealed Make sure that all chimney cleanouts are tight fitting and will not perm...

Страница 25: ...combustible materials Also refer to the Also refer Clearances to Combustibles section 2 Remove door See Maintenance and Service Glass Door Removal 3 Remove wrapping material from log and embers and c...

Страница 26: ...or inputs exceeding 50 000 Btu h 15kW but not exceeding 100 000 Btu h 30kW Clearances are in accordance with local installation codes and the requiremenets of the gas supplier 7 Most vent caps can be...

Страница 27: ...Collar Screw supply line has been installed Cutting any sheet metal parts of the fireplace in which the gas fireplace insert is to be installed except as tested for the floor is prohibited The includ...

Страница 28: ...tions or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The unit is equipped with a three prong grounding plug for your protection a...

Страница 29: ...proper workmanship like manner This access hole must be plugged with non combustible insulation after the gas supply line has been installed A shut off valve is supplied with this unit The appliance a...

Страница 30: ...olution after completing the required pressure test Pilot Adjustment Screw Manifold Pressure Tap Inlet Pressure Tap Servo Regulator Pilot Solenoid Burner Solenoid Gas IN Adjusting The Pilot Flame does...

Страница 31: ...el options and it may also be used with the E44 Trimmable Surround The Base Shelf and Riser are sold separately Installation 1 If unit is running turn it off and allow it to cool completely 2 When usi...

Страница 32: ...placed just inside the fireplace opening for a cleaner appearance 4 Cut along the preferred line from direct measurements of offset and remove any sharp edges 5 The panel can be touched up with a hig...

Страница 33: ...six 6 screws through each side extension and into the cabinet sides Side Cabinet Extensions Top Cabinet Extension The E44 is shipped with the cabinet extensions in Setting 1 This setting is used for t...

Страница 34: ...upright in front of the fireplace with the top mounting flange pointing towards the fireplace Slide the panel up until the surround panel hooks engage the mounting slots on the unit see Figure 46 Fir...

Страница 35: ...rs and the burner tube NOTE Follow the steps in the reverse order for reassembly Figure 47 The firebox with log set and media removed Figure 48 Carefully remove the front liner if installed on the bot...

Страница 36: ...ntoured and some contain pin holes to make alignment easier Using the pictures provided carefully set the logs in place see Figures 53 through 62 Figure 53 Install the back log on top of the pilot on...

Страница 37: ...ible clump the wool together and separate it using the supplied brush over the burner tube It is best to have less ember wool strands of Embaglow overtop of the wool Place coals on the air deector in...

Страница 38: ...lace the center front chunk log on the log grate close to the center with the front edge resting on the right mid log Figure 61 Finally rest the left and right front chunks on the log grate and burner...

Страница 39: ...alled replaced watch for ignition at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Then remove the glass and make sure none of the burner ports ar...

Страница 40: ...e LED indicator will blink one 1 time in intervals 3 Parasitic Pilot Flame the LED indicator will blink two 2 times in intervals 4 System Lock out the LED indicator will blink three 3 times in interva...

Страница 41: ...ot burner assembly orifice Pilot will not remain lit Problem with Flame Sensor circuit Check for proper connection of the Flame Sensor to the IFC board Check pilot for full flame impingement around Fl...

Страница 42: ...temperature Flame lifting Leak in vent pipe Check for leaks in vent connections Improper vent configuration Check vent configuration with manual Check positioning of baffle plate Terminal may be re ci...

Страница 43: ...50 3204 Battery Holder Wire Harness 50 3305 10 Proflame 2 IFC 50 3791 IFC Wire Harness 0 584 924 50 3030 IFC ON OFF Jumper Only 50 3205 11 Proflame 2 Transmitter TMFSLA 50 3265 12 E44 Door Complete 5...

Страница 44: ...44 Parts Diagram Components 1 2 4 3 11 9 10 6 5 7 16 8 14 12 13 15 18 17...

Страница 45: ...45 Notes...

Страница 46: ...ety screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused fro...

Страница 47: ..._________________________________________ PHONE ___________________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ d...

Страница 48: ...48 MANUFACTURED BY SHERWOOD INDUSTRIES LTD 6782 OLDFIELD RD SAANICHTON BC CANADA V8M 2A3 www enviro com May 2022 C 15553...

Отзывы: