TO TEST VALVE PRESSURES (INPUT RATES):
The pressure taps are located on the front side of the valve (see Figure 27).
1. Remove valve control knobs, then remove control panel.
2. Using a long flat bladed screwdriver, turn set screw one (1) turn counter-clockwise to loosen.
3. Place
5
/
16
in (8 mm) I.D. hose over the pressure taps.
4. Check pressures using a manometer.
5. When finished, remove hose and tighten set screw.
6. Re-install the control panel and knobs. Pointer on knobs can be removed and oriented correctly to
point at the right location.
Always check for gas leaks with a soap and water solution after completing the required
pressure test.
NEVER USE AN OPEN FLAME FOR LEAK TESTING.
23
Initial Installation
QUALIFIED INSTALLERS ONLY
1
2
3
4
5
I
tem
n
umber
D
escrIptIon
1
Control Knob
(On/Off/Pilot)
2
Gas Flow Adjustment
Knob
3
Pilot Adjustment
Screw
4
Inlet Pressure Test
Point
5
Outlet Pressure Test
Point
Figure 27: Valve Details.
Table 6: Valve Details.