Leaning

 t

he

 g

Lass

:

When the fireplace has cooled

, remove the face of the fireplace along with the glass. See 

M

aintenance

 

a

nd

 S

ervice

 - G

laSS

 d

oor

 r

eMoval

Check the gasket material on the back of the glass, making sure that 

it is attached and intact.  
During a cold start up, condensation will sometimes form on the glass. This is a normal condition with all 

fireplaces. However, this condensation can allow dust and lint to cling to the glass surface.  Initial paint 

curing of the appliance can leave a slight film behind the glass, a temporary problem.  The glass will need 

cleaning about two weeks after installation. 

Use a mild glass cleaner and a soft cloth

Abrasive 

cleaners will damage the glass and painted surfaces. 

Depending on the amount of use, the glass 

should require cleaning no more than two or three times a season. 

Do not clean the glass when it is 

hot.

c

Leaning

 t

he

 f

iRebox

:

Remove the logs carefully, as they are very fragile.  Carefully clean any dust off the logs and remove 

any lint from the burner and pilot. At this time, inspect the ceramic burner for cracking. If a problem is 

suspected, contact the dealer. Check the logs for deterioration or large amounts of soot; a small amount 

on the bottom side of the logs is normal. Replace the logs as shown in the 

S

econdary

 i

nStallation

 - l

oG

 

S

et

 i

nStallation

 section. If any logs are damaged, contact your nearest ENVIRO dealer.

 

R

ePLacing

 

the

 g

Lass

:

The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory 

replacement is required (see 

P

artS

  l

iSt

).  Wear  gloves  when  handling  damaged  glass  door  assembly 

to prevent personal injury. Do not operate with the glass front removed, cracked or broken.  Removal 

and replacement of the glass from the door 

must

 be done by a licensed or qualified service person. 

The glass must be purchased from an ENVIRO dealer. No substitute materials are allowed. 

Remove the door (see page 12).  The replacement glass will come with a new gasket installed. Remove 

any silicone remnants from the door.  Apply high temperature silicone to the two vertical faces of the 

door and install the new piece of glass with gasket (be sure to maintain edge clearances).  Apply even 

pressure to the glass to allow the silicone to adhere to the gasket material. 

f

Lashout

 g

uaRD

:

This unit is equipped with a flashout guard that automatically stands up to serve as protection if a delayed 

ignition were ever to occur. The flashout guard should always be in the down position (Figure 8) during 

regular operation of the stove. If the guard is for some reason left in the up position (Figure 9) it will 

effect the volume of convective air discharging from the front of the stove and must be reset to the down 

position.

Guard Down

Guard Up

Figure 8: Flashout Guard Down (Default)

Figure 9: Flashout Guard Up

Содержание Berkeley-Nova

Страница 1: ...perty damage personal injury or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier Version Fran aise www enviro com fr html 4001609 W A...

Страница 2: ...plumber or gas fitter when installed within the Commonwealth of Massachusetts Other Massachusetts code requirements Flexible connector must not be longer than 36in a shut off valve must be installed o...

Страница 3: ...e performed by a qualified installer service agency or gas supplier This installation must conform to local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 o...

Страница 4: ...Removal 12 Glass Door Removal 12 Burner Removal 13 Fuel Conversion 14 Initial Installation 17 Preparation for Installation 17 Clearance to Combustibles 17 Direct Vent 18 Venting Clearances 18 Approve...

Страница 5: ...TERS CAN CGA 2 17 M91 R2014 GAS FIRED APPLIANCES FOR HIGH ALTITUDES CSA P 4 1 15 TESTING METHOD FOR MEASURING ANNUAL FIREPLACE EFFICIENCY This ENVIRO Berkeley Fireplace Has been certified for use with...

Страница 6: ...rkeley Dimensions Rating Label Lighting Instructions Location The rating label and lighting instructions are located on a plate hanging on the back of of the unit 29 5 16 75 5 cm 4 5 8 11 7 cm 30 1 4...

Страница 7: ...next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any pho...

Страница 8: ...flames to Figure 47 on page 35 The ideal flame will be blue at the base and light orange above The flames should be of medium height If the flames look like this no venturi adjustment is needed If the...

Страница 9: ...e Berkeley DO NOT FORCE IT If the unit is going to be serviced turn off the electrical power to the unit as well NOTE When the unit is turned on for the first time it should be turned onto high with t...

Страница 10: ...eed of the blower The blower is pushing the heat from the fireplace into the room Gas Control Valve Dull click when turning on or off this is the valve opening and closing Maintenance And Service Rout...

Страница 11: ...allation Log Set Installation section If any logs are damaged contact your nearest ENVIRO dealer Replacing the Glass The glass in the fireplace is a high temperature ceramic If the glass is damaged in...

Страница 12: ...in Figure 12 To replace the glass door simply reverse the above procedure Warning Do not touch or attempt to remove the glass door if the fireplace is not completely cold WARNING Never operate the fir...

Страница 13: ...3 Place your hands in the air slots in the burners as shown in figure 14 then pull forward and lift up to dis engage the venturi tubes 4 Continue to lift up and rotate the burner approx 45 degrees as...

Страница 14: ...en L and P c Turn the pilot head a turn clockwise back to its original position Fuel Conversion TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before...

Страница 15: ...e the screw clockwise until a torque of 9 inch lbs WARNING Do not over tighten the screw It is recommended that you grip the wrench by the short side f Verify that if the conversion is from NG to LPG...

Страница 16: ...e until the correct flame is achieved 13 Relight the main burner in both the HI and LO positions to verify proper burner ignition operation and proper flame appearance figure 47 page 35 Confirm the in...

Страница 17: ...ng joist Check stove and flue system clearance requirements Locate the stove where it can be accessed by a gas supply line Locate the stove in a large and open room that is centrally located in the ho...

Страница 18: ...and arrangement Because the length of the vertical and horizontal sections dramatically affects the burning efficiency of the fireplace certain guidelines have been set in Initial Installation Allowa...

Страница 19: ...sheild 46DVA WT 4WT Wall thimble 46DVA SC SC Storm collar 46DVA WFS 4CS Fire stop 46DVA WS WS Wall strap support band 46DVA F6 4FA Flashing 0 12 to 7 12 roof pitch 46DVA F7 4FB Flashing 8 12 to 12 12...

Страница 20: ...Berkeley A termination guard 50 3266 is required when the termination is within 7 2 13m of grade Figure 24 Minimum Vent Length Approved horizontal termination Approved through wall thimble 24 61 cm Mi...

Страница 21: ...at may be opened C 12 in 30 cm Clearance from permanently closed window to prevent condensation D 24 in 60 cm Vertical clearance to ventilated soffit located above the terminal within a horizontal dis...

Страница 22: ...number of elbows is ideal as they tend to disrupt air movement Using 45 elbows is preferable to using 90 elbows Also a shorter vent system will perform better than a longer one The total length of ho...

Страница 23: ...e and Service section The firebox baffle must be removed next by removing the two front screws using a T20 screwdriver Figure 27 Next remove the restrictor set screws and install the restrictor at the...

Страница 24: ...n The air gap prevents excessive heat from possibly melting the vinyl siding 5 Horizontal pipes must be supported every 3 feet 914 mm Plumber s all round strap will suffice 6 When running horizontal p...

Страница 25: ...n the vent termination should be pointing up Run a bead of non hardening mastic around the edges of the vent cap to make a seal with the wall Ensure the proper clearances to combustibles have been mai...

Страница 26: ...lashing to the roof with roofing nails Use a non hardening sealant between the uphill edge of the flashing and the roof Insure the roofing material overlaps the top edge of the flashing Verify that yo...

Страница 27: ...ng should be framed to 10 254 mm x 10 254 mm inside dimensions in the same manner as shown in Figure 23 45 elbows x2 Wall strap Plumber s tape connected to wal strap 4 Any occupied areas above the fir...

Страница 28: ...the wires are not pinched between the adaptor and the collar and or flue outlet Ensure that the opening of the Drafthood Adaptor is not blocked or obstructed Optional remote control receiver ON OFF Re...

Страница 29: ...venting Venting Restrictions The vent lengths below are measured from the floor to the top of the flex venting and cannot run in the horizontal dimension Minimum 10 ft 3 05m Maximum 30 ft 9 14m SPILLA...

Страница 30: ...afthood into a non combustible chimney the following optional finishing technique can be used CAUTION Installations where the flue connector or venting connects to or passes through combustible walls...

Страница 31: ...s individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psig 3 45 KPa Always check for gas leaks with a soap and water sol...

Страница 32: ...s For Electrical Installations or The National Electrical Code ANSI NFPA 70 in the US WARNING The electrical grounding instructions must be followed The fan kit is equipped with a three prong groundin...

Страница 33: ...e unit Then remove the glass door by releasing the top spring latches 2 Next install the ember bed assembly as shown in Figure 41 by holding onto the slots in the ember bed The ember bed must be held...

Страница 34: ...Figure 46 Final Top Log 6 Next Install the left and right top logs as shown in Figure 45 Note the locating notches on the bottom side of both logs areas highlighted 7 Install the last log on top on t...

Страница 35: ...tion at ALL the burner ports If a long delay is noticed turn the appliance off and wait for it to cool down Then remove the glass and make sure none of the burner ports are blocked Maintenance Once a...

Страница 36: ...taining bolts Figure 48 using a 1 4 socket and remove the damaged screen while noting the orientation Install the new screen 50 3243 by simply re installing the retaining bolts Re install the cast doo...

Страница 37: ...screw check pilot head for damage Check thermocouple voltage at valve It must be greater than 5 mV If low replace thermocouple Air in gas line pilot dies while knob is depressed Bleed line Check gas l...

Страница 38: ...50 1421 13 Heyco Strain Relief EC 044 14 Domestic Power Cord 115v EC 042 15 Log Set 9 pieces 50 3234 16 Ceramic Burner Assembly 50 3233 17 Front Door Glass w Gasket 16 875 x 21 0625in 50 3235 18 Fron...

Страница 39: ...39 Parts List 21 1 24 25 2 9 5 14 13 19 20 23 3 11 12 4 6 10 7 8 18 16 22 17 27 15 26...

Страница 40: ...led Antique Chestnut 50 3249 31 Cast Skirt Painted 50 3250 Cast Skirt Enameled Antique Chestnut 50 3251 32 Cast Right Side Painted 50 3252 Cast Right Side Enameled Antique Chestnut 50 3253 33 Cast Lef...

Страница 41: ...ar une personne de service certifi ou qualifi Chaud pendant le fonctionnement Ne touchez pas Des br lures graves peuvent en r sulter Gardez les enfants les v tements meubles essence et autres liquides...

Страница 42: ...42 Notes...

Страница 43: ...ty screen mesh Exclusions An expanded list of exclusions is available at www enviro com help warranty html This warranty does not cover Damage as a result of improper usage or abuse Damage caused from...

Страница 44: ...______________________________ MODEL ___________________________________ SERIAL NUMBER ___________________________ DATE OF PURCHASE _____________ dd mm yyyy DATE OF INSTALLATION ___________ dd mm yyyy...

Отзывы: